Zanussi MULTI BUILT-IN OVENS ZBM 762 Libretto di istruzioni - Pagina 16
Sfoglia online o scarica il pdf Libretto di istruzioni per Forno Zanussi MULTI BUILT-IN OVENS ZBM 762. Zanussi MULTI BUILT-IN OVENS ZBM 762 16. Electric oven
Anche per Zanussi MULTI BUILT-IN OVENS ZBM 762: Libro di istruzioni (15 pagine)
SECURING THE OVEN TO THE CABINET
Fit the appliance into the cabinet recess.
Open teh oven door and secure the oven to the kitchen
cabinet with four wood screws, which fit the holes
provided in the oven frame (Fig.13).
When installing an electric plate hob over the oven, the
hob's electrical connection and the oven's one have to
be carried out separately, for security reasons and to let
the oven be taken off the unit easier, if necessary.
ELECTRICAL CONNECTION
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load;
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the socket or the double pole switch used for
the electrical connection can be easily reached with
the appliance built in the forniture unit.
This appliance is supplied with a type H05 RR-F
connection cable, section 3 x 1,5 mm
plug, able to carry the load specified on the rating
plate, must be fitted to the cable. This is a three-wired
cable, with the earth wire marked yellow-green.
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system,
a double pole switch must be installed between the
appliance and the electricity supply, with a minimum
gap of 3 mm. between the switch contacts and of a type
suitable for the required load in compliance with the
current rules. The earth wire must not be interrupted by
the double switch pole.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 50 C higher
than the room temperature.
After the connection is carried out, test the heating
elements for about 3 minutes.
TERMINAL BLOCK
The oven has an easily accessible terminal block,
which is meant to work with an electric single-phase
rate of 230 V.
The manufacturer disclaims any
responsability should all the safety
measures not be carried out.
64
2
. A suitable
(Fig. 14)
FO 0290
In-Column Recess Dimensions (Fig. 11)
FO 2154
Undertop Recess Dimensions (Fig. 12)
FO 0039
Fig. 13
Fig. 14
FO 2159