Zanussi ZGG62414 Manuale d'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale d'uso per Piano cottura Zanussi ZGG62414. Zanussi ZGG62414 16. Product manaul
Anche per Zanussi ZGG62414: Manuale d'uso (48 pagine), Manuale d'uso (20 pagine)

Zanussi ZGG62414 Manuale d'uso
A
B C
A) End of shaft with nut
B) Washer
C) Elbow
Connection to the gas supply should be with
either rigid or semi-rigid pipe, i.e. steel or cop-
per.
The connection should be suitable for connect-
ing to R 1/2 (1/2 BSP male thread).
When the final connection has been made, it is
essential that a thorough leak test is carried out
on the hob and installation.
Make sure that the main connection pipe does
not exert any strain on the hob.
If you use flexible metal pipes make sure that
they agree to ISO 10380 and ISO 10807
standards. Be careful they do not come in
touch with mobile parts or they are not
squeezed. Also be careful when the hob is put
together with an oven.
Important! It is important to install the elbow
correctly, with the shoulder on the end of the
thread, fitted to the hob connecting pipe.
Important! Failure to ensure the correct
assembly will cause leakage of gas.
Important! Make sure that the gas supply
pressure of the appliance obeys the
recommended values.
Rigid connection:
Carry out connection by using metal rigid pipes
(copper with mechanical end).
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burn-
er.
10
3. With a socket spanner 7 remove the injec-
tors and replace them with the ones which
are necessary for the type of gas you use
(see table in "Technical Information" chap-
ter).
4. Assemble the parts, follow the same pro-
cedure backwards.
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type
of gas supply. You can find this plate in the
package supplied with the appliance.
If the supply gas pressure is changeable or dif-
ferent from the necessary pressure, you must fit
an applicable pressure adjuster on the gas sup-
ply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-pass
screw position.
A) The by-pass screw
• If you change from natural gas G20 20 mbar
to liquid gas, fully tighten the adjustment
screw in.
• If you change from liquid gas to natural gas
G20 20 mbar, undo the by-pass screw ap-
proximately 1/4 of a turn.
Warning! Make sure the flame does not
go out when you quickly turn the knob
from the maximum position to the minimum
position.
Electrical connection
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
A
www.zanussi.com