Zanussi ZKT 652 DBV Manuale di installazione e istruzioni per l'uso - Pagina 18

Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Piano cottura Zanussi ZKT 652 DBV. Zanussi ZKT 652 DBV 24. Ceramic glass hob

Installation Instructions

Safety instructions
The laws, ordinances, directives and standards in
force in the country of use are to be followed (safety
regulations, proper recycling in accordance with the
regulations, etc.)
Installation may only be carried out by a qualified
electrician.
The minimum distances to other appliances and
units are to be observed.
Anti-shock protection must be provided by the in-
stallation, for example drawers may only be installed
with a protective floor directly underneath the appli-
ance.
The cut surfaces of the worktop are to be protected
against moisture using a suitable sealant.
The sealant seals the appliance to the work top with
no gap.
When building in, protect the underside of the appli-
ance from steam and moisture, e.g. from a dish-
washer or oven.
Avoid installing the appliance next to doors and un-
der windows. Otherwise hot cookware may be
knocked off the rings when doors and windows are
opened.
1
WARNING!
Risk of injury from electrical current.
• The electrical mains terminal is live.
• Make electrical mains terminal free of voltage.
• Observe connection schematic.
• Observe electrical safety rules.
• Ensure anti-shock protection through correct in-
stallation by a qualified electrician.
• The appliance must be connected to the electrical
supply by a qualified electrician.
1
IMPORTANT!
Risk of injury from electrical current.
Loose and inappropriate plug and socket connec-
tions can make the terminal overheat.
• Have the clamping joints correctedly installed by a
qualified electrician.
• Use strain relief clamp on cable.
• In the event of single-phase or two-phase connec-
tion, the appropriate mains cable of type H05BB-F
Tmax 90° (or higher) must be used.
• If this appliance's mains cable is damaged, it must
be replaced by a special cable (type H05BB-F
Tmax 90°; or higher). The latter is available from
the Customer Care Department.
• This appliance's mains cable is fixed directly to the
board. If the mains cable is damaged, it must only
be replaced by a qualified ecletrician or our Cus-
tomer Care Department.
38
A device must be provided in the electrical installa-
tion which allows the appliance to be disconnected
from the mains at all poles with a contact opening
width of at least 3 mm.
Suitable isolation devices include line protecting cut-
outs, fuses (screw type fuses are to be removed from
the holder), earth leakage trips and contactors.
Sticking on the seal
• Clean the worktop around the cut-out area.
• Stick the single-sided adhesive sealing tape pro-
vided on the underside of the hob around the out-
side edge ensuring that it is not stretched. The two
ends of the tape should join in the middle of one
side. After trimming the tape (allow it to overlap by
2-3 mm), press the two ends together.