Position the new charcoal filter in the
position marked and while holding the
filter replace the fixing hooks as
illustrated.
This appliance can be a possible fire
hazard if the grease and charcoal filters
are not cleaned and replaced as
recommended.
Changing the Spot Lamps
Remove the two screws fixing the lighting
support.
Remove the spot lamp from the holder by
pulling the lamp downwards.
Replace the spot lamp by inserting the
two pins at the base of the lamp into the
holes in holder and pushing into position.
Replace the lighting support, ensuring it is
located correctly and fix back into position
using the two screws.
If one of the spot lamps has failed to function
check that the lamp is fully seated into the lamp
holder. If lamp failure has occurred then it
should be replaced with a 12V 20W M262
halogen spot lamp.
Replacement filters and lamps can be
obtained from your local Service Force
Centre.
CLEANING AND MAINTENANCE