BURNER
Semi-rapid
Auxiliary
Oven
Grill
GAS BURNERS FOR LPG G30 28-30 mbar
NORMAL POW-
BURNER
Triple Crown
Rapid
Semi-rapid
Auxiliary
Oven
Grill
GAS CONNECTION
WARNING! Before you connect the
gas, disconnect the appliance from the
electricity supply or switch off the fuse
in the fuse box. Close the primary
valve of the gas supply.
The gas pipe in the appliance has two endings. You
can connect the gas supply to either one of them.
The pipe that is not used must be clogged with the
pipe closer, which added to the appliance.
Use a fixed connections or use a flexible stainless
steel pipes in compliance with the regulation in
force. If you use flexible metallic pipes, make sure
they do not come in touch with mobile parts and
they are not squeezed.
NORMAL POWER kW
2.0
1.0
3.6
2.5
GAS RATE g/h
ER kW
3.2
2.7
2.0
1.0
3.6
2.5
REDUCED POWER kW
0.45
0.35
1.5
1.6
REDUCED POWER
232.7
225.4
145.4
72.7
261.8
181.8
WARNING! When installation is
complete, make sure that the seal of
each pipe fitting does not leak. To
check the seal use a soap solution, not
a flame.
FLEXIBLE NONMETAL PIPES CONNECTION
If you have an easy access to the connection, you
can use a flexible pipe. The flexible pipe must be
tightly attached by clamps.
In installation always use the pipe holder and the
gasket. The flexible pipe can be applied when:
INJECTOR MARK 1/100
INJECTOR MARK
kW
1/100 mm
1.8
1.1
0.43
0.35
1.5
1.6
mm
96
70
126
111
90x
80
71
50
90
80
25