Sfoglia online o scarica il pdf Manuale per Apparecchiature industriali California Air Tools 1810C. California Air Tools 1810C 8. 10 gallon casting pressure pot

Maintenance and Storage
1. Close the air flow to the equipment.
2. Release all air pressure in the tank by pulling the safety valve ring until the pressure
subsides.
3. Rotate the tank regulator handle "T" counterclockwise until you do not feel any tension in the
spring.
4. Loosen the metal screws, remove the wing nuts, and open the lid to one side.
5. Loosen the metal rings on the gun nozzle about three turns.
6. Open the air supply.
7. Place a cloth or rag onto the mouthpiece like a receptacle and cover, and then pull the trigger.
This action will force the remaining material in the hose to go back into the tank.
8. Empty and clean the tank and parts that have been in contact with the material by using a
solvent recommended by the manufacturer.
9. Pour some solvent into the tank.
10. Place the lid and the wing nuts and tighten the thumbscrews.
Cleaning Instructions
WARNING!
Always shut off air pressure at the source and bleed off all pressure in the Tank by gently pulling
the safety valve ring before loosening thumb screw and clamps remove lid.
Turn off the main air supply to the tank. Remove all pressure from the tank by pulling the ring on the
safety valve until the pressure bleeds down. Turn the T-handle adjusting screw on the regulator
counter-clockwise until no spring tension is felt. Loosen thumb screws, tip clamps back and tip the tank lid
to one side. Empty and clean tank and parts which come in contact with the material. Use a suitable
solvent. Pour solvent into the tank. Replace the lid and tighten the thumb screws and clamps and spray
until clean appears.