Trouble Shooting
WARNING:
If any of the following symptoms appears during your operating, stop using the tool immediately, or
serious personal injury could result.
Only a qualified persons or an authorized service center can perform repairs or replacement of tool.
Disconnect tool from air supply before attempting repair or adjustment. When replacing O-rings or
Cylinder, lubricate with air tool oil before assembly.
PROBLEMS
Air escaping from port on
regulator cap
Pressure dropping slowly
on gauge.
Air leak at the lid gasket.
Gauge not registering air
pressure.
Safety valve popping off.
Note: Repairs should be carried out by a qualified person.
POSSIBLE CAUSES
Broken or damaged
diaphragm in regulator.
Dirty or work valve seat in
regulator.
Defective lid gasket.
Thumb screw not tight.
Defective air gauge.
Tank pressure to high.
Defective valve.
CORRECTION
Replace regulator
Replace regulator
Replace lid gasket.
Tighten thumb screws.
Replace air gauge
Reduce tank pressure to 20-50 PSI.
Replace safety valve.