Directed Electronics 3100 Manuale di installazione - Pagina 15

Sfoglia online o scarica il pdf Manuale di installazione per Allarme auto Directed Electronics 3100. Directed Electronics 3100 16. Car security

Directed Electronics 3100 Manuale di installazione

Troubleshooting

Door input does not immediately trigger full alarm. Instead, first I hear
chirps for 3 seconds:
That's how the progressive two-stage door input works! This is a feature of
this system. This is an instant trigger, even if the door is instantly re-closed,
the progression from chirps to constant siren will continue.
Closing the door triggers the system, but opening the door does not:
Have you correctly identified the type of door switch system? This often
happens when the wrong door input has been used.
System will not passively arm until it is remotely armed and then dis-
armed:
Are the door inputs connected? Is the H1/6 Blue wire connected to the
door trigger wire in the vehicle? Use the H1/5 Green or the H1/7 violet
Door input does not respond with the progressive trigger,
wire instead.
but with immediate full alarm:
Does the LED indicate that the trigger was caused by the impact sensor?
Table of Zones
(See
extreme sensitivity, may be detecting the door unlatching before the door
switch sends its signal. Reducing the sensitivity can solve this problem.
The Valet/Program button does not work:
Is it plugged into the correct socket? The button plugs into the Blue 2-pin
port.
The LED system status indicator does not work:
Is the LED plugged into the correct socket? The LED plugs into the White
2-pin port.
Starter interrupt does not work:
Is the correct wire being interrupted? If the vehicle starts when the starter
interrupt is disconnected, the wrong wire has been cut.
Is the Yellow H1/9 ignition wire connected to true ignition? Wire must be
powered in the run and start positions in order to work properly.
© 2011 Directed Electronics. All rights reserved.
section of this guide.) The impact sensor, if set to