Clarke CEB103 Manuale di istruzioni per il funzionamento e la manutenzione - Pagina 4
Sfoglia online o scarica il pdf Manuale di istruzioni per il funzionamento e la manutenzione per Pompa dell'acqua Clarke CEB103. Clarke CEB103 13. Water pump
ELECTRICAL CONNECTIONS
WARNING: THIS MACHINE MUST BE EARTHED.
It is strongly recommended that installation should only be carried out by a
qualified electrician in accordance with I.E.E. Regulations. However, in the
further interests of safety we would emphasize the following:-
This pump should be connected to a standard domestic 230 volt (50Hz),
electrical supply and we strongly recommend that the connection be made
via a Residual Current Device (RCD) and a suitably rated circuit breaker.
IMPORTANT: Should the supply be taken from a normal 13 amp socket, then
the plug used must be to BS 1363 standard, and the cable conductors
should be connected in accordance with the following colour code:
Green & Yellow - Earth or marked with a letter "E" or Earth symbol "
Blue - Neutral or terminal marked with a letter "N".
Brown - Live or terminal marked with a letter "L".
FUSE RATING
The fuse in the plug must be rated at 5 amps.
T
he pump MUST be wired according to the
diagram on the right, and ensuring the
following precautions are strictly observed:
1. The cable used must be of sufficient size to
ensure it is a tight fit in the cable gland.
2. Ensure the cable gland is correctly used.
The clamp must firmly clamp the outer
cable sheath and NOT the conductors.
3. Fit a crimp style ring terminal to the earth
wire and make sure that it is correctly
connected to the earth terminal.
The ring terminal should be placed between the two washers, and the
screw suitably tightened.
WARNING: DO NOT ATTEMPT ELECTRICAL INSTALLATION WORK IF YOU
ARE IN ANY DOUBT AS TO HOW IT SHOULD BE PROPERLY CARRIED OUT.
CONSULT A QUALIFIED ELECTRICIAN.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
4
".