Clarke GSE1 Manuale di istruzioni per il funzionamento e la manutenzione - Pagina 6

Sfoglia online o scarica il pdf Manuale di istruzioni per il funzionamento e la manutenzione per Pompa dell'acqua Clarke GSE1. Clarke GSE1 13. Submersible pump
Anche per Clarke GSE1: Manuale di istruzioni per il funzionamento e la manutenzione (8 pagine)

Clarke GSE1 Manuale di istruzioni per il funzionamento e la manutenzione

Operation

Connect a length of delivery hose (not supplied) to the outlet spigot of the pump (GSE and
GSE1A pumps require1" hose, GSE2 and GSE2A require 2" hose). Suitable hose is available
from your nearest CLARKE dealer.
CLARKE submersible pumps are designed for use with fresh water. Avoid using your pump
with salt water, or with water containing chemicals, as these can cause damage to the
pump. If the pump does come into contact with salt or water containing chemicals, wash
it immediately. GSE pumps will handle small solids in suspension, making it suitable for draining
sumps, pits and excavations etc.
Inspect the pump regularly to check that the base inlet is clear of leaves or other debris.
Any blockage of mud or leaves can be cleared by washing the pump in fresh water, or by
using a hose to flush fresh water back through the pump outlet connector. Never switch on
the pump with the outlet connected to the mains water supply.
GSE 1A, 150A and 2A pumps incorporate an automatic float switch. As the water level rises,
the switch will float, and start the pump. As the water level falls, so will the float switch,
which in turn will switch the pump off. The position of the float switch can be adjusted by
repositioning the cable in its clip.
For the float switch to operate correctly it must be able to move freely. When putting the
pump into position, ensure there is nothing which might impede the float switch movement.
GSE pumps are fitted with automatic overload protection. If the motor overheats (because
of an obstruction in the pump, or pumping warm water, for example), it will shut off
automatically. Switch the pump off and isolate from the main electric supply, check for
blockages, and remove, allow the motor to cool down before attempting to restart. The
thermal overload will normally reset in a few minutes.
This pump should require little or no maintenance other than regular cleaning. If the pump
starts to show signs of wear or damage, contact you nearest CLARKE dealer for advice. Do
Not use the pump if there is any damage to the mains supply or float switch cable.
Do Not attempt to repair the pump yourself, (other than to replace listed parts on pages 10
& 12), as you may invalidate your guarantee, and damage the waterproof seal of the
pump.
If using this pump in a garden pond, please note that there is a small quantity of oil in the
pump seal. If the pump seal is worn or damaged, oil may leak out, and appear as a film on
the surface of the water. Although harmless to people, the oil must be cleared to prevent
any possible harm to pond life. Disconnect the pump from the electrical supply, remove it
from the pond, clear the oil and contact the CLARKE service department for advice, on
020 8988 7400.
Once satisfied the pump is installed, and taking all the necessary safety and electrical
precautions as described on pages 4 & 5, plug into the mains supply and switch ON.
NOTE:
If the pump does not deliver immediately, it is possible that an air lock exists, Leave the
pump for approximately one minute in order for the air lock to be displaced. If necessary
switch OFF and On again, the pump should now deliver water, if not check all hose
connections etc.
SUITABLE HOSE, and SPARE/REPLACEMENT HOSE ADAPTERS ARE
AVAILABLE FROM YOUR NEAREST CLARKE DEALER
-6-