Alemite 585-B1 Manuale di servizio - Pagina 6
Sfoglia online o scarica il pdf Manuale di servizio per Strumenti Alemite 585-B1. Alemite 585-B1 9. Cordless grease gun
SER 585-A1
Specific Safety Rules
WARNING
The gun can develop high pressure up to
10,000 psi (690 bar). Rupture of components can
inject grease into skin and eyes, causing serious
injury and possible amputation. If injured, seek
immediate medical attention.
Do not operate without proper safety protection,
gloves, and goggles. Hold hose at spring guard
only. Do not use if hose is damaged or worn.
Inspect hose before each use. Use only Alemite
340067 Grease Whip Hose.
This gun uses lubricants, that may be flammable
and poisonous if ingested. Do not use gun near
open flame or other fire hazards. Read all
warnings on lubricants before using this gun.
Use ear protection to reduce the risk of induced
hearing loss.
Disconnect battery pack from gun before changing
accessories or storing the gun.
Warning! To reduce the risk of injury, the
user must read the instruction manual.
Separate collection. This product must not be
disposed of with normal household waste.
Loading and Priming the Gun
NOTE: Refer to Figure 2 for component
identification on the following procedures.
Cartridge Loading
1. Unscrew Grease Cylinder (36) from the gun.
2. Pull the follower rod and engage the groove in the
follower rod with the slot in the Grease Cylinder cap.
3. Remove the plastic cap from the cartridge.
4. Apply a film of grease to the exposed inside surface of
the cartridge.
NOTE: This is only necessary for a virgin
gun.
5. Insert the cartridge into the Grease Cylinder.
• Remove the tabbed seal from the cartridge.
6. Screw the Grease Cylinder onto the gun.
7. Disengage the follower rod from the slot in the Grease
Cylinder cap.
• Push the follower rod into the Grease Cylinder.
Revision (9-09)
Suction Loading
1. Unscrew Grease Cylinder (36) from gun.
2. Insert the head of the Grease Cylinder below the
surface of the grease.
3. Slowly pull the follower rod outward from the Grease
Cylinder cap until the groove is visible.
4. Engage the groove in the follower rod with the slot in
the Grease Cylinder's cap.
5. Screw the Grease Cylinder onto the gun.
6. Disengage the follower rod from the slot in the Grease
Cylinder cap.
• Push the follower rod into the Grease Cylinder.
Loader Pump
WARNING
The gun can be equipped with an optional
low-pressure Loader Fitting. Do not substitute with
a high-pressure grease fitting. Personal injury can
occur due to excessive pressure.
The use of a grease fitting will void the warranty.
CAUTION
The Loader Fitting on the gun must mate with the
loader coupler. The pump may not operate if the
components are not compatible.
1. Pull the follower rod and engage the follower by
rotating the rod.
2. Seat the Loader Fitting into the loader coupler.
• Push down to hold the coupler valve open.
3. Operate the pump and view the movement of the
follower rod.
4. Discontinue pump operation once the groove on the
follower rod is visible.
5. Disengage follower rod from follower and push into
the Grease Cylinder.
6
Cordless Grease Gun
Alemite, LLC