Alemite 3575 Series Manuale - Pagina 4
Sfoglia online o scarica il pdf Manuale per Strumenti di misura Alemite 3575 Series. Alemite 3575 Series 8. Oil control handle with mechanical meter
Mechanical Meter Oil Control Handle
Meter Disassembly
1 Remove rubber boot (1).
2 Unscrew the 4 x Phillips head screws (7),
from the underside of the handle body (26)
and remove register assembly (4).
3 Using 4 mm Allen key remove 4 screws
(43) from the underside of the handle body
(26).
Notice
!
Take care when removing reg-
ister housing as the outlet shaft (12) and
assembly are also removed.
4 Remove register housing (6) assembly.
5 Remove gearbox housing (18) assembly.
6 Remove rotors (19, 20).
7 Clean and inspect all parts. Replace any sus-
pect, worn or damaged parts.
Gear and O-Ring
replacement (register
casting)
1 Pull bevel gear off the shaft (5) from inside
register housing (6).
2 Remove gear (13), circlip (11), washer (10),
O-Ring (9) and shaft (12) from the under-
side of register housing.
3 Assembly is a reversal of disassembly.
Facia Replacement
4 Remove register assembly (4) and remove
the register bracket clip (3).
Notice
!
Use all new parts when reas-
sembling the gear and shaft assembly.
Notice
!
Refer to Meter Disassembly Parts A and B.
5 Remove facia (2).
Initial Release 10-15
6 Assembly is a reversal of disassembly.
Notice
!
Clean all components prior to
assembly.
Meter Reassembly
1 Replace rotors (19, 20) into body casting
(26) (see fig 3 for correct positioning).
Notice
!
Turn rotors by hand to confirm
correct assembly. If rotors do not turn
freely. (refer to fig 3 for correct rotor
position).
2 Fit O-Ring (21) to the handle body (26).
3 Fit gears (15,16,17) into gear box (18).
4 Replace O-Ring (14) on gear box housing
(18) and position gearbox assembly on top
of handle body (26).
Notice
!
Gears are marked in order of
assembly 1, 2 and 3.
Gear shaft (12) on register housing as-
sembly (23), must be located through
gear 2 (16) inside gearbox and fitted into
location hole in gearbox housing (18).
5 Replace register housing assembly (6) on
top of gearbox housing assembly (18).
6 Replace 4 Allen head screws (43) and screw
the meter assembly together.
7 Fit bevel gear (5) inside the register housing
(6).
8 Fit register assembly (4) into register
housing (6) and replace 4 x Phillips head
screws (7).
4
Notice
!
Check correct operation of rotors by
latching lever and apply low pressure
air into oil inlet. Meter should register
flow.
19
26
Figure 3 Correct rotor position
Alemite, LLC
SER 3575A
20