Base drive kits are always factory installed in either standard or custom (CTO) models. Upgrade drive kits
can be factory installed or can be installed as a field upgrade for supported standard or custom models.
HDD Rear Kit configuration notes:
The HDD Rear Kit (00KA058) is installed in place of the PCIe slots 1 and 2 (see the "I/O expansion
options" section), and it includes a special riser that provides PCIe 3.0 x16 slot 3. No other riser
cards can be used when the HDD Rear Kit is installed.
145 W and 135 W processors cannot be used when the HDD Rear Kit is installed.
The HDD Rear Kit is connected to the SAS expander on the 10-drive backplane.
The following table lists possible internal storage configurations.
Table 8. Internal storage configurations (FC=Feature Code, PN=Part Number, qty=quantity)
Drive bay
Drive
Storage controller
type
bay
qty
2.5-inch
4
SAS/SATA
hot-swap
8
10
12
2.5-inch
4
SATA
Simple
Swap
8
Lenovo System x3550 M5
Drive kits required
1x M1215; or
Factory installed:
1x M5210; or
1x System x3550 M5 4x 2.5" HS HDD Kit (FC A59W)
1x N2215
1x M1215; or
Factory installed:
1x M5210; or
1x System x3550 M5 4x 2.5" HS HDD Kit (FC A59W); and
1x N2215
1x System x3550 M5 4x 2.5" HS HDD Kit PLUS (FC A59X)
Field upgrade for the 4-drive bay model:
1x System x3550 M5 4x 2.5" HS HDD Kit PLUS (PN 00KA055)
1x M1215; or
Factory installed:
1x M5210; or
1x System x3550 M5 10x 2.5" HS HDD Kit (FC A5A0)
1x N2215
1x M1215; or
Factory installed:
1x M5210; or
1x System x3550 M5 10x 2.5" HS HDD Kit (FC A5A0); and
1x N2215
1x System x3550 M5 2x 2.5" HS HDD Rear Kit (FC A5A2)
Field upgrade for the 10-drive bay model:
1x System x3550 M5 2x 2.5" HS HDD Rear Kit (PN 00KA058)
Integrated
Factory installed:
8-port
1x System x3550 M5 4x 2.5" SS HDD Kit, Non-Raid (FC A59Y)
6 Gbps SATA
(no RAID
support)
1x M1215; or
Factory installed:
1x M5210; or
1x System x3550 M5 4x 2.5" SS HDD Kit, HW RAID (FC A5A6)
1x N2215
Integrated
Factory installed:
8-port
1x x3550 M5 4x 2.5" SS HDD Kit, Non-Raid (FC A59Y); and
6 Gbps SATA
1x x3550 M5 4x 2.5" SS HDD Kit PLUS, Non-Raid (FC A59Z)
(no RAID
Field upgrade for the 4-drive bay model:
support)
1x x3550 M5 4x 2.5" SS HDD Kit PLUS, Non-Raid (PN 00KA056)
1x M1215; or
Factory installed:
1x M5210; or
1x x3550 M5 4x 2.5" SS HDD Kit, HW RAID (FC A5A6); and
1x N2215
1x x3550 M5 4x 2.5" SS HDD Kit PLUS, HW RAID (FC A5A7)
Field upgrade for the 4-drive bay model:
1x x3550 M5 4x 2.5" SS HDD Kit PLUS, HW RAID (PN 00KA060)