2. Complete the following steps to add commands to the <serial>_Node2_system.bat file:
a. Open the <serial>_Node2_system.txt file (where <serial> is the serial number of the
standard I/O book in node 2). This file was saved from node 2 of the IBM System
x3950 X6 8-socket system during the Backup vital product data (VPD) procedure.
b. Locate the IBM server machine type and model string in the <serial>_Node2_
system.txt file. This string has the following format:
SYSTEM_PROD_DATA.SysInfoProdName=<IBM_machine_type_model>
where: <IBM_machine_type_model> is a 7–character field that combines the 4–
character machine type and the 3–character model number.
c. Change the IBM server machine type to the Lenovo server machine type by
replacing the IBM server 4-character machine type, 3837, with the Lenovo server
4-character machine type, 6241. The 3-character model number remains
unchanged between the IBM and Lenovo servers.
For example, if the original IBM server machine type and model number was
3837FT4, the new Lenovo server machine type and model number would be
6241FT4.
d. Add a command line to the batch file for the Lenovo server machine type and
model created in the previous step (this model number varies based on the original
IBM server model number), following the form:
asu64 set SYSTEM_PROD_DATA.SysInfoProdName <Lenovo_machine_type_model>
--host <IMM_IP> --user <IMM_userid> --password <IMM_password>
where:
• <Lenovo_machine_type_model> is a 7–character field that combines the new
Lenovo 4–character machine type and the original IBM 3–character model
number
• <IMM_IP> is the IMM IP address
• <IMM_userid> is the IMM user name
• <IMM_password> is the IMM password
e. Add a command line to the batch file for the Lenovo server product identifier,
following the form:
asu64 set SYSTEM_PROD_DATA.SysInfoProdIndentifierEx "<product_id>" --override
--host <IMM_IP> --user <IMM_userid> --password <IMM_password>
where:
• <product_id> is Lenovo System x3950 X6 for 8-socket systems
• <IMM_IP> is the IMM IP address
• <IMM_userid> is the IMM user name
• <IMM_password> is the IMM password
f. Locate the IBM server serial number in the <serial>_Node2_system.txt file. This
string has the following format:
SYSTEM_PROD_DATA.SysInfoSerialNum=<serial_number>
where: <serial_number> is a 7–character field for the product serial number.
Note: The Lenovo server system serial number remains unchanged: it is the same
serial number that was used for the IBM server.
g. Add a command line to the batch file for the Lenovo server serial number, following
the form:
.
Chapter 1
IBM to Lenovo server upgrade procedure
19