Nikon Nivo Series Manuale dell'interfaccia di comunicazione - Pagina 8
Sfoglia online o scarica il pdf Manuale dell'interfaccia di comunicazione per Camera Accessories Nikon Nivo Series. Nikon Nivo Series 34. Hardware
Anche per Nikon Nivo Series: Manuale di istruzioni (32 pagine)
Nikon Communication Interface Manual
5-4. Command list
a) Remote control commands
Command
Remarks
Taking a distance measurement in Precise mode.
$MSR
Resolution and average of current settings are used in the measurement.
When the "Data output after MSR" feature is set to ON, the measured data is to be
output in the specified format.
Taking a distance measurement in Normal mode.
$TRK
Resolution and average of current settings are used in the measurement.
When the "Data output after MSR" feature is set to ON, the measured data is to be
output in the specified format.
Initiate continuous (tracking) distance measurements. (AVE=0)
$HTR
Resolution is fixed to COARSE mode.
When the "Data output after MSR" feature is set to ON, the measured data is to be
output in the specified format.
Change displays. The same function as the "DSP" key on the instrument.
$SHV
$RHA
Reset horizontal angle to zero.
$BZR
Beep for "n" x 50msec. ("n" = Length of the sound; 1~9)
$DON
Set "output SD after each measurement" feature ON.
$DNX
Set "output SD/HA/VA after each measurement" feature ON.
$DOF
Cancel $DON and $DNX command.
Set "output SD after each measurement" feature ON. After this command, SD from
$DSN
the very first measurement is to be output and "$DOF" is set automatically.
Set "output SD/HA/VA after each measurement" feature ON. After this command,
$DSX
SD/HA/VA from the very first measurement is to be output and "$DOF" is set
automatically.
$HAN
Change the display on the instrument to the basic measurement screen (BMS).
$ANG
Change the display on the instrument to the BMS.
$REC
Output the measured data (PT/HT /SD/HA/VA) with 7-digit PT.
$COF
Turn the Lumi-Guide OFF.
$CON
Turn the Lumi-Guide ON.
$LPT
Turn the Laser pointer ON or OFF.
*$REC
Output the measured data (PT/HT /SD/HA/VA) with 16-digit PT.
b) Data Set commands
Command
Remarks
!AVE
Set an average count of the measurement
!PNO
Set a default point number/name
!PSM
Set the prism constant
!T-P
Set the current temperature and pressure
!HAN
Set the horizontal angle (by 7 digits)
!CND
Set a set of initial settings on the instrument
P8/34
Confidential