Armstrong CD72SR Manuale di installazione e funzionamento - Pagina 8
Sfoglia online o scarica il pdf Manuale di installazione e funzionamento per Unità di controllo Armstrong CD72SR. Armstrong CD72SR 11. Control disc steam trap
6. Gently clean the surface with a soft damp cloth as shown below. Inspect the surfaces fro any
nicks, gouges or any other visible signs of damage.
7. Place the disc on top of the seat. The groove in the disc should be facing downwards. Ensure
that the disc is centered on the seat.
8. Apply anti seize paste to the inside of the cap on the surface, spread out evenly. Do not
apply any other lubricant on the surface.
Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information.
8
Apply anti-seize paste
North America • Latin America • India • Europe / Middle East / Africa • China • Pacific Rim
armstronginternational.com
Clean and insect the surface.