7. Check for Gas Leaks

Once the unit is reassembled and the electrical connection restored, open the manual gas shut
off valve and check the unit for gas leaks.
1.
Use an approved leak detention method to check all junctions shown with arrows A
through E in Figure 20.
07/28/2014
AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288
Kit # 62632006
Checking for Gas Leaks
Figure 20: Gas Leak Check Locations