Electrical connection :
All electrical connections MUST be carried out by an authorised
technician and in accordance with local regulations.
As a minimum 'Classic' recommends that the following standards are
maintained :
•
•
•
Prior to connecting the appliance, ensure that the voltage and the supply
fuse complies with the rating plate on the appliance.
3.2.1
Electrical rating :
Within the 'Classic' range several of the 500mm² basket appliances can
be either down rated or up rated electrically, such a procedure MUST be
carried out by a 'Classic' approved technician.
The down / up rating of the machine is carried out by configuring the
terminal block within the appliance to the following
13 Amp – Single phase
•
Links removed between L1, L2 and L3
•
Ensure link remains between neutrals (N)
30 Amp – Single phase
•
Ensure all link remains between lives
terminals (L1, L2 and L3)
•
Ensure link remains between neutrals (N)
Three phase
To ensure safety standards are maintained, converting a single phase appliance to
three phase requires conversion kit 'KIT-05-3PH', which must be ordered from
'Classic' and installed as instructed in the above kit.
All appliances are connected via a residual current device
(R.C.D.) or earth leakage protection device.
EN 60204
Supply isolator switch must have all pole separation of more
than 3mm.
EN 60335
The appliance must be connected to a equi-potential
conductor, the connection stud is located at the rear of the
appliance (a suitable ring terminal shall be required), this is in
addition to the earthed electrical supply.
Page 3