ARO Ingersoll-Rand PX10P-YPS Series Manuale dell'operatore - Pagina 7
Sfoglia online o scarica il pdf Manuale dell'operatore per Pompa dell'acqua ARO Ingersoll-Rand PX10P-YPS Series. ARO Ingersoll-Rand PX10P-YPS Series 8. 1” diaphragm pump
107
. 105
U
133
135
. 134
U
111
k 137
136
107
236
Figure 3
Product discharged from exhaust outlet.
S
Check for diaphragm rupture.
S
Check tightness of (6) diaphragm screw.
Air bubbles in product discharge.
S
Check connections of suction plumbing.
S
Check O" rings between intake manifold and inlet side fluid caps.
S
Check tightness of (6) diaphragm screw.
Motor blows air or stalls.
S
Check (176) check valve for damage or wear.
S
Check for restrictions in valve / exhaust.
PD10P X
PARTS LIST / PX10P-X AIR SECTION
173 k
118
169 k
k 174
121
167
140
141 k
233
Notch
200 k
Insert screwdriver here to remove (233) adapter plate.
138 k
139 k
MAJOR
VALVE
A replacement Major Valve Service Assembly is available separately, which includes the following:
637395 1 for models PD10P X: 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,
176 (2), 200, 233 and 236 (4)
637395 2 for models PE10P X: 76, 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,
176 (2), 200, 233 and 236 (4)
TROUBLE SHOOTING
168 k
172 k
171 k
170
166 k
132 k
176 k
101
.
TORQUE REQUIREMENTS
NOTE: DO NOT OVERTIGHTEN FASTENERS.
ALL FASTENERS ARE METRIC.
Torque (105 and 134) Screw to 35 40 in. lbs (4.0 4.5 Nm).
LUBRICATION / SEALANTS
k Apply Lubriplate FML 2 grease to O" rings, U" Cups & mating parts.
U Apply anti seize compound to threads at assembly.
Low output volume, erratic flow, or no flow.
S
Check air supply.
S
Check for plugged outlet hose.
S
Check for kinked (restrictive) outlet material hose.
S
Check for kinked (restrictive) or collapsed inlet material hose.
S
Check for pump cavitation - suction pipe should be sized at least as
large as the inlet thread diameter of the pump for proper flow if high
viscosity fluids are being pumped. Suction hose must be a non col
lapsing type, capable of pulling a high vacuum.
S
Check all joints on the inlet manifolds and suction connections.
These must be air tight.
S
Inspect the pump for solid objects logged in the diaphragm chamber
or the seat area.
PILOT VALVE
PART GROUP
173 k
118
121
174 k
181
103
201
,
Page 7 of 8