Aerial DH 18 Manuale di istruzioni - Pagina 11
Sfoglia online o scarica il pdf Manuale di istruzioni per Deumidificatore Aerial DH 18. Aerial DH 18 14.
7.Technical data
Among other things, many different components which are installed in the
condensation dryer decide on the capacity of the device. Since these components
can never be completely identical, in accordance to DIN EN 810 the capacity may
deviate up to 5% of specified capacity.
Generell:
Operational range:
Protection class:
Voltage:
Air volume:
Power consumption:
Noise level:
refrigerant:
capacity:
8. Service & Maintenance
ATTENTION
When performing any repair or maintenance, the general safety rules and
provisions must be adhered to!
In order to guarantee a troublefree function of the dryer the device should be
cleaned regularly. The following procedure is instead recommended:
Ø Switch OFF the air dryer
Ø Disconnect mains cable
Ø Remove filter for cleaning. Filter can be washed under flowing water.
Ø Visual inspection: check tank, hose connector and attached hose for blockage,
if necessary change it
Ø Clean case with moist cloth. Do not use aggressive Detergent
Ø Insert new or cleaned filter
Ø Put main plug into the sucket
Ø Switch on dehumidifier.
This cleaning is without fail regularly required!
No other maintenance work is required for the air dryer.
+15°C up to + 32°C / 40% r.h. up to 95% r.h.
IP X0
230 V / 50 Hz
160 cbm/h
max. 390 Watts
46 dB(A) in 1 mtr. distance
R 134a
18
l/24h at 30°C / 80% r.h. (390 Watt)
10,5 l/24h at 27°C / 60% r.h. (350 Watt)
7,2 l/24h at 20°C / 60% r.h. (300 Watt)
page 11 of 14