Abbriata Miniroto M50 Manuale di avvio rapido - Pagina 15

Sfoglia online o scarica il pdf Manuale di avvio rapido per Macchine agricole Abbriata Miniroto M50. Abbriata Miniroto M50 19.

Abbriata Miniroto M50 Manuale di avvio rapido
Abbriata M50 Quick Start Guide
Copyright 2015 Tractor Tools Direct

Bale sensor and siren

The baler signals that the bale has achieved its desired size and weight by sounding a siren. The siren is turned
off during shipping. To switch it on, flip the switch on the black box. The siren runs on a 9 volt battery. It is
inside the black box. If, needed remove the box, open and change the battery as needed.
Figure 22 location of siren switch and battery
To test the siren, open the cover on the other side and push up on the switch trip arm.
Figure 23 testing the siren is on

Bale density

The setting of how tightly the bales are compressed is controlled by what hole the arm is in. The hole on top
will produce the lightest bale, while the hole on the bottom will produce the heaviest. You may not be able to
use the heaviest setting with all materials. The heaviest setting (bottom hole) is likely to break a shear pin. Start
nd
at the 2
hole down from the top and go from there.
Page | 14