CAMDEN CX-EPD1289L Manuale di istruzioni per l'installazione

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Per serrature CAMDEN CX-EPD1289L. CAMDEN CX-EPD1289L 7. Electric preload rim strike

E l ec t r if i e d Lo ck s , R e l ay s a n d Time rs
CX-EPD1289L
Electric Preload RIM Strike
INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
(2) 4-PIN power connector
(1) 3-PIN door status connector
(1) Installation Jig
1. DESCRIPTION
Camden CX-EPD1289L Preload RIM strike for pullman latches
offers the very best strike quality and performance. The
strike design delivers unparalleled application flexibility, with
field selectable voltage, fail safe/fail secure operation and
mechanical adjustment of the strike body.
2. SPECIFICATIONS
Voltage
Current Draw
Static Strength
Dynamic Strength
Preload (Fail-Secure Only)
Endurance
Latch Projection
Fire Rating
Mode
Mechanical Adjustment
Operation
Duty
Latch Bolt Monitor
Dimensions (Body)
UL 294 Performance
Levels
(4) 1/4 - 20 x 1-1/4'' Screws
(4) M3 x 6 Screws
3
4 ''
12/24V AC/DC
[19.8mm]
560mA @ 12 VDC
280mA @ 24 VDC
1,500lbs. (UL Verified)
70 ft-lbs.
15lbs.
1,000,000 Cycles (Factory Tested)
250,000 Cycles (UL Verified)
3/4"
UL 10C/CAN4-S104
3 hrs. (Fail Secure Only)
Field Selectable
Fail Safe/Fail Secure
Strike Body
AC-Buzz, DC-Silent
Continuous
SPDT, 100mA @ 24V DC Resistive
9-3/16"H x 1-15/16"W x 3/4"D
(233mm x 49mm x 19.8mm)
- Line Security = Level I
- Attack Level = Level I
- Endurance Level = Level IV
- Standby Power = Level I
(1) MOV
(1) Cover plate
3. DIMENSIONS
3
4 ''
[19.8mm]
UL 1034
UL 294
UL10C/
CAN4-S104,
3hr. Fire rating
1 15
1 15
16 ''
16 ''
[49.0mm]
[49.0mm]
3
4 ''
[19.8mm]
1 15
1 15
16 ''
16 ''
[49.0mm]
[49.0mm]
9 3 16 ''
[233.0mm]
Page 1 of 7