TROUBLESHOOTING
Problem
Lock has no holding force
Lock will hold a screwdriver or set of metal pliers,
but the door will not lock.
Lock is operating and locking but it hums against
the armature plate.
There is a latency of the lock not releasing after
power is removed.
DC Power Supply
(filtered & regulated)
DC Power Supply
(filtered & regulated)
+
MOV
MAINTENANCE SCHEDULE
_________________________________________________________
Company Name:
Door Location
Opening New Doors to
Innovation, Quality and Support!
Check the power supply. Voltage should be 12 to 24 VDC +/- 10%.
Check wiring of power supply and releasing devices.
Check to ensure the armature plate is correctly aligned to the maglock. Follow the armature
plate mounting instructions on the template and the installation manual 40- 82B236
Check that the power supply is filtered DC. The humming is caused by AC on the DC supply.
A proper filtered and regulated DC power supply will resolve the issue.
Refer to Figure A and check the placement of any suppression devices. Residual magnetism
is related to the presence of electricity (i.e., capacitance) in the lock circuit. Degaussing or
dimpling the lock are not advised since it will cause unintended consequences.
Switch
+
+
Switch
Maglock
+
Date
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
Delayed Egress Lock Maintenance Manual
Solution
Maglock
Recommended 
placement of switch to 
ensure instant release.
Placing the RTE switch 
(push plate or PIR) on the 
Maglock
wrong leg may cause the 
bond to collapse more 
slowly than expected. 
interrupts the positive 
wire and not the negative 
Maglock
Never connect a 
parallel reverse diode 
Notes
File: Delayed_Egress_Maintenance_
Manual.indd
Revision: Sept 27th 2021
Part No.: 40-82B292
INSTAL L AT ION INS T RUCT IONS
Ensure the switch 
wire.
as shown.
Initial