CAME 319U36EN Manuale di installazione - Pagina 10

Sfoglia online o scarica il pdf Manuale di installazione per Pannello di controllo CAME 319U36EN. CAME 319U36EN 19. Control panel for 24v gearmotors

7 Selecting functions

10-WAY DIP-SWITCH
DIP
.
F
POS
UNCTION ACTIVATED
1 ON -
Automatic closing - The automatic closing timer activates at the closing endpoint. The pre-set time is adjustable, but it's in any
case subject to any safety device intervention and does not activate after a total "stop" or in case of power failure.
2 OFF -
"Open-stop-close-stop" function with (2-7) button and transmitter.
2 ON -
"Open-close" function with (2-7) function and transmitter.
3 ON -
"Open only" function with transmitter.
4 ON -
Opening and closing prefl ashing - After either an opening or closing command, the fl ashing light connected on 10-E, fl ashes
for 5 seconds before beginning to execute the command.
5 ON -
Obstacle detection - With motor idle (door-leaf closed, open or after a total stop command), it prevents any movement if the
safety devices (e.g. photocells) detect an obstacle.
6 ON -
Maintained action - Door opens and closes only if button is kept pressed.
7 ON -
Ramming function activated - At each opening command, the door presses against the strike plate for one second, facilitating
the release operation for the electro lock connected on terminals 11-S.
8 OFF -
Partial stop - Door stops is in movement which consequently triggers automatic closing, insert the safety device on terminal
(2-C3);if unused, set DIP switch to ON.
9 OFF -
Total stop - This function stops the door and then excludes any automatic closing cycle; use either the buttons or transmitter to
resume movement. Insert safety device on [1-C2]; if unused, set DIP switch to ON.
10 OFF - Reopening during closing - The photocells, detect an obstacle during the closing phase of the door leaf, triggering an inversion
of travel direction, until door is fully open; Insert the safety device on terminal (2-C1); if unused, set DIP switch to ON.
4-WAY DIP-SWITCH
1 - Must stay OFF
2 - Must stay OFF
3 ON - Activates the safety tests to check photocell effi ciency.
4 - Unused