LUBRICATING THE TRAPEZOID BOLT
1. Set the heatbed to the lower position (Menu → Lower heatbed).
2. Move heatbed towards to you.
3. Lubricate trapezoid bolts and linear guides:
- Push grease into the grease nipple and around of the left linear carriage (Fig.73). It is located at the top of the
liner carriage. Push grease out by pressing the lubricator nozzle firmly against the grease nipple and pressing
smoothly the lubricator lever once.
Fig.73 Linear carriage grease nipple
4. Apply grease to the raceway of the trapezoid bolts (left and right) Fig.74
5.
using a wooden stick (or other blunt tool).
-Apply the grease every 5 cm.
Fig.74 Trapezoid bolt raceway
6. Raise the heatbed (Menu-> Upper heatbed).
7. Lower the heatbed (Menu ->Lower heatbed).
8. Collect excess grease from linear carriages and trapezoid bolt nuts using a paper towel.
9. Apply grease to the raceway of the trapezoid bolts (left and right) using a wooden stick (or other blunt tool).