CAME v6000 Manuale di installazione - Pagina 5
Sfoglia online o scarica il pdf Manuale di installazione per Apriporta del garage CAME v6000. CAME v6000 17. For garage doors

GENERAL INSTALLATION INSTRUCTIONS
Installation must be carried out by qualified and experienced personnel in compliance with applicable regulations.
Preliminary checks
Before starting installation:
•
Provide a suitable single-pole disconnection device, with a maximum of 3 mm between the contacts, to disconnect the power supply;
•
Prepare suitable piping and ducts for routing the electrical cables, ensuring protection against mechanical damage;
•
Make sure that any connections within the container (made to ensure the continuity of the protection circuit) are fitted with additional insulation compared to the
other internal conductor parts;
•
Check that the door is well-balanced. If halted at any intermediate point, it must maintain the position;
•
If there is a pedestrian opening in the door, a safety switch must be added, connected to the STOP input, in order to prevent the operator from being operated when
the pedestrian door is open.
Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with current standards and regulations. The
figure shows some examples of installer's tools.
Types of cables and minimum thicknesses
Connection
Power supply
Photocell transmitters
Photocell receivers
Control devices
Antenna connection
☞ If the cables differ in length compared to what is shown in the table, the cable cross-section is determined according to the actual current draw of the devices connected and
according to the provisions of the IEC EN 60204-1 standard.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and distances. When connecting products
that are not specified in this manual, please refer to the documentation provided with said products.
Example of a system
1.
Operator with receiver
2.
Slide rail
3.
Release device
4.
Transmission arm
5.
Key selector
6.
Photocells
7.
Pushbutton panel
8.
Sensitive edge
Cable type
FROR CEI
20-22
IEC EN
50267-2-1
RG58
5
6
RX
Cable length
Cable length
1 < 10 m
10 < 20 m
4G x 1.5 mm 2
4G x 2.5 mm 2
2 x 0.5 mm 2
2 x 0.5 mm 2
4 x 0.5 mm 2
4 x 0.5 mm 2
2 x 0.5 mm 2
2 x 0.5 mm 2
max. 10 m
3
4
7
6
TX
8
Cable length
20 < 30 m
4G x 4 mm 2
2 x 0.5 mm 2
4 x 0.5 mm 2
2 x 0.5 mm 2
1
2