Alto CS 1020 PE Manuale di istruzioni per l'uso - Pagina 12
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Idropulitrice Alto CS 1020 PE. Alto CS 1020 PE 20.
Cleaning and Care Agents (Additives):
Choose dosage at dosing valve, according to the existing requirement, and set it.
Important to observe:
On all interruptions of operation, even very short ones, be sure to put the switch on '0' and to release pressure
- this being of utmost importance!
Attention:
Do not allow the machine to be in operation - with closed trigger gun on/off - for more than 10 minutes, since
this would affect the high pressure pump.
Temperature is thermostat-controlled. This safety feature protects your machine from being overheated. If
temperature rises beyond the value adjusted, the burner disconnects fully automatic.
The pressure gauge indicates the working presse. If pressure increases beyond the working pressure as such
maybe the high presssure nozzle is clogged, or the machine has to be decalcified. If cleaning and care agents are
used, the bins containing them are cot allowed to get empty, since this would bring about intake of air.
Water quantity, pressure and temperature are infinitely variable.
Never pull, crush, twist and/or buckle the high pressure hose. Genuine Wap high pressure hoses are to be used
exclusively. They are complying with the 'German Directives for Ejectors of Liquids (High pressure cleaners) ' .
Fittings and hoses are accordingly marked.
Please follow our Service Instructions (Maintenance) Chapter 5 of this Manual.
4.4
Stopping ration
Dosing valve on position "O" .
Switch on position "piston pump". Have machine run for about 1 minute, then move switch on "0".
Stop drive motor (refer Honda Operating Instructions). Actuate trigger gun on/off, until machine will be
depressurized.
Lock the trigger.
Close water-tap.
For operation during winter season:
Place machine into a frostproof room. Should this not be possible, please proceed as follows:
Close water-tap. Start drive motor. Actuate trigger gun on/off several times. At the same time, fill in an antifreeze
(appcox. 4 l) into water tank. Your machine is frostproof, as soon as antifreeze solution emerges from the spray
lance.
We recommend as follows:
At temperatures around the freezing point, the fuel starts to solidify (paraffine extraction). This may cause
problems re. the starting of the burner. We, therefore, recommend to add a special agent to the fuel thus
improving the solidifying and flowing properties. Such agents are available from professional fuel dealers. The
admixture being: 2l of the additive for approx. 1000l of fuel, to be made at emperatures higher than 8°C.
4.5
Inspections
Upon requirement - but at least every 12 months - the ejectors of liquids (high pressure cleaners) have to be
thoroughly checked over by experts, with regard to operational safety and reliability.
On machines standing idle, however, inspection may be deferred until the next start-up.
The instructions issued by the manufacturer are to be followed and adhered to. Our expert mechanics will be
available to you at any time. The results of inspections are always to be put down in writing.
The heating mechanism is al firing plant, which is to be checked over and controlled in conformity with the locally
prevailing Rules and Regulations.
A documented routine maintenance system consisting of regular inspection, testing and repair by a competent
person, should be established.