Cameron WHEATLEY 820 Series Manuale di installazione, funzionamento e manutenzione - Pagina 7
Sfoglia online o scarica il pdf Manuale di installazione, funzionamento e manutenzione per Unità di controllo Cameron WHEATLEY 820 Series. Cameron WHEATLEY 820 Series 8. Swing check valve
Figure 1:
2
1
MAINTENANCE SCHEDULE
The frequency of the maintenance depends on the service conditions. Please contact the factory
regarding the maintenance schedule for particular service conditions.
RECOMMENDED SPARE PARTS
RECOMMENDED SPARE PARTS LIST GUIDE
QTY. OF VALVES
10
25
50
100
Installation, Operation and Maintenance Manual
3
6
5
4
7
REPAIR KIT
1
1
2
3
BODY / COVER MATERIAL
DUCTILE IRON
SIZE
TORQUE FT-LBF.
1-1/2 & 2 116-128
3
143-157
4
114-125
REPAIR KIT CONTENTS
PART NAME
Cover O-Ring
Clapper Seal
Clapper
7
D I S T R I B U T E D V A L V E S
WCC, LCC, CF8M, ALUMINUM BRONZE
TORQUE FT-LBF.
234-257
174-201
232-255
QUANTITY
1
1
1
02/2011 / IOM-WHE-CHECK-822