RESOLUTION
To lessen the exposure to the listed vulnerabilities, system administrators need to install the I/Port updates
that ClearCube has provided. Each update is provided in a zipped file containing the Technical Bulletin
describing the update, and these files:
The local installer, in a folder named Stand Alone.
A batch file named
A folder named IPORT-CLIENT
The Grid Center remote installer, in a folder named GCUpdate.
A batch file named
A zipped folder named
The local installer is run by physically carrying the files to the I/Port on a Mass Storage Device such as a
key drive, and then executing the
should select all the updates they intend to install, load them all onto a Mass Storage Device, and install
the entire set of updates at each I/Port in turn.
The Grid Center remote installer is run from the Grid Center Console, in the Update View, and can be
applied to multiple I/Ports or I/Port groups simultaneously. If installing updates using Grid Center, system
administrators should select all the updates they intend to install, then "push" the updates one at a time to
all the I/Ports that need to be updated.
INSTALLING UPDATES LOCALLY
To install an update locally, do the following:
1. Load the update file onto a Mass Storage Device (MSD) such as a key drive.
2. At the I/Port, log in as administrator. Press and hold the Shift key and select Logoff from the Start
menu. Keep the Shift key depressed until the Administrator Login dialog box is displayed. The factory
default Administrator account is
changed in the User Accounts control panel.
3. Insert the USB storage device into an available USB port.
4. Browse to the folder on the storage device that contains the update file.
5. Double-click the
Update.bat
Note: Do not press any keys during the update. Allow it to run undisturbed.
INSTALLING UPDATES REMOTELY USING GRID CENTER
To install an update remotely with Grid Center, do the following:
1. Load the update files onto a volume accessible by the Grid Center Console.
2. Start Grid Center (if it is not already running).
3. From the Update View, select an individual I/Port or an I/Port Group to update.
4. In the I/Port Update View dialog box, enter the path and name of the
browse for this).
5. Enter the path and name of the
6. Press the Update button.
ClearCube Technology 8834 Capital of Texas Hwy N Suite 140 Austin, Texas 78759 voice 512 652 3500 www.clearcube.com
Update.bat
updateGC.bat
IPORT-CLIENT.zip
batch file. If installing updates locally, system administrators
Update.bat
and the default password is
administrator
file. The update installs automatically and reboots the I/Port.
file (you can browse for this).
updateGC.bat
ClearCube Public Technical Document
Document Code: TB0096JS
. These can be
clearcube
file (you can
IPORT-CLIENT.zip