ACS-200
Quick Start Guide

2 Communicating with the ACS-200

2.1

Serial Communication

2.1.1

Serial Terminal Software

A serial terminal software such as Tera Term, Real Term, Hyper Terminal, Putty etc is
required to test the communication with the ACS-200.
Download, install and run such a program of your choice. Tera Term is used here in this
document for the purposes of providing examples. All other serial terminal software will
have either same or similar settings and options.

2.2 Connecting to the Unit

Run the serial terminal software, create a new serial connection by selecting Serial as the
connection type and then selecting the COM port the ACS-200 is connected to.
All available COM ports will appear in the list of ports as COMx, x being the port number
(COM4 in the example below). The ACS-200 will appear on the list of devices as USB-SERIAL
CH340.
2.2.1

Serial Port Settings

Required settings for the
serial port connection are:
Speed/Baud Rate
Data Bits
Parity Bits
Stop Bits
Flow Control
9600
bps
8
bit
None
1
bit
None
3