Camlogic PFG-86/X Installazione e manutenzione - Pagina 2

Sfoglia online o scarica il pdf Installazione e manutenzione per Strumenti di misura Camlogic PFG-86/X. Camlogic PFG-86/X 2. Bladed level gauges

Camlogic PFG-86/X Installazione e manutenzione
ELECTRICAL WIRING
The conductors forming the power supply and signal carrying cable must have an adequate cross-section so that
the current density, in each conductor, is no higher than 4 A/mm². One of these is used only for the earthing of
the level gauge. The cross-section of the conductors must also be adequate in relation to the length of the cable
used to avoid a drop in voltage along the cable over the values prescribed by the regulations on the subject.
It is likewise reccomended to use flexible cables with an adequate outside diameter for the cable entries used
( not supplied ) to ensure a perfect seal of the cable clamp on the power supply and signal carrying cable.
Use exclusively cable entries certified according to directive 2014/34/EU, Category 2 and EN 60079-31.
CAUTION :
The terminal box contains a screw whose position is marked by the
symbol
made in the casting ( Fig.3 ) which has the function of making the ground
connection for the level gauge. This screw must be connected to the yellow-green
conductor ( only green for the USA ) of the power cable. The ground connection of
the level gauge, through the yellow-green conductor, is compulsory.
- The external earthing has to be carried out by the installator.
- The equipment has to be protected against impact and electrostatic inside the silo.
- The user has to protect the equipment circuits with fuses against short circuit.
- The max. surface temperature considered is without dust and not safety distance.
By the terminal box there is the wiring plate ( Fig.1 ) which has printed on it the
wiring diagram for the power supply and use of the level gauge. Always check
that the mains voltage and frequency correspond to those given on the plate of the level gauge before powering up.
REFERENCE FIGURES
346,5
92,5
138
16
33
105
ø2" 1/2 Gas
PFG-86
316,5
92,5
21
203
8 mm thick
PFG-86/F
283,5
92,5
55
36
100
33
22
ø2" 1/2 Gas
PFG-86/C
302
92,5
54,5
95
2 mm thick
4 vanes model AC3 screw in stainless steel
The manufacturer CAMLogic declares under its own responsability that the product PFG-86/./././. answers to the requisites
of the European Directive 2014/34/EU in consideration of the standards : EN IEC 60079-0:2018 and EN 60079-31:2014.
The permitted ambient temperature range is -20 to +70 °C.
Notified corporate body that releases the examination and entrusted of the periodic overseeing TÜV ITALIA.
Certificate number TÜV IT 13 ATEX 070 Rev.1.
Instructions Manual No. 00625 97.06 - Rev. 05
part of it may be disclosed without written authorization from CAMLogic.
This manual, even after the sale of the level gauge, is lent and remains the property of the Manufacturer.
SGC2014
Firma: Giovanni Guazzetti (AD)
100
SLEEVE
18
Screw ø5 MA
65
6 equidistant ø7 mm holes
16
70
344,5
108
136,5
ø2" 1/2 Gas
15,5
22
6 equidistant ø7 mm holes
60
EU
DECLARATION OF CONFORMITY
All the information contained in this manual is confidential and no
For connections to the terminal board use
fork cable terminals.
For the grounding connection use an eyelet
cable terminal.
Double ø1/2" Gas horizontal
cable inlet on the right side
MAINTENANCE
CAMLogic
maintenance. Possible extraordinary maintenance
is
restricted
deteriorated by use.
The gauge must not be lubricated; the shaft,
the only moving part, is mounted on ball
bearings with permanent lubrication.
FLANGE
Reccomended spare part:
-
Geared motor
-
Return spring
-
Neoprene seal ring ( Corteco )
-
Braket complete with limit switch
and terminal board
-
Ball bearings
WARRANTY
CAMLogic, in addition to the terms of the supply
contract, guarantees its products for a period
100
of twenty-four ( 24 ) months from the date of
shipment. This warranty is expressed only in the
repair or replacement free of charge of parts that,
after careful examination by the Manufacturer,
turn out to be defective.
ø32
Model AC4 screw
Warranty, excluding all liability for direct or
indirect damage, is considered to be restricted
PFG-86/X
to only defects in materials and has no effect
if the parts returned turn out to have been
FLANGE
anyhow dismantled, tampered with or repaired
by anyone other than the Manufacturer.
Warranty likewise excludes damage deriving
ø33
from negligence, carelessness, bad or improper
use of the level gauge, or from bad handling
by the operator and faulty installation.
Warranty is moreover forfeit if non-genuine
spare parts have been used.
A
returned
PFG-86/X/F
warranty,
Marking:
II 1/2 D Ex ta/tb IIIC T85°C Da/Db
- Data di produzione: 10/2019
level
gauges
need
no
to
replacing
parts
level
gauge,
even
must
be
shipped
carriage
00625 97.06 - Rev. 05
Fig.3
routine
that
are
if
under
free.