Troubleshooting Guide
Problem
The table stops suddenly during
operation and the control unit beeps
once. The control unit beeps when
the UP s or DOWN t button is
pressed.
The table stops suddenly and the
control unit beeps slowly five times.
The table stops suddenly and the
control unit beeps rapidly five times.
During operation, the table stops
moving and reverses direction
40 mm.
When in its lowest position, the table
will not move when the UP s or
DOWN t button is pressed.
The table does not move and the
control unit does not emit any
sounds.
After installation, the table wobbles
or vibrates.
After installation or after a long
time without use, the table columns
vibrate or make noise.
Possible Cause
Overuse — operation of the table
has exceeded the duty cycle
(continuous operation time).
The electrical current needed has
exceeded the amount provided.
There is no signal to the control unit
or the legs are not level.
The anti-collision feature has
engaged.
Incomplete re-initialization — there
was no beep and no "bump up" from
the lowest position.
There is no power to the table.
The screws were not fully tightened.
The internal leg components need to
be actuated.
Wait 20 minutes to resume normal use. After 20 minutes, the control unit will
reset and operation can continue.
1) Check that the top load on the table is balanced from side to side.
2) Check that the top load is less than the rated weight.
3) Unplug the power cord. Press either button on the handset. Then plug the
power cord back in. Re-initialize the table by pressing and holding the
UP s and DOWN t buttons at the same time until the control unit beeps
and the table moves to its lowest position, then "bumps up" slightly.
1) Unplug and reconnect all cords and cables at the control unit, ensuring that
all connections are fully engaged.
2) Check that all cables are undamaged.
3) Check that the circuit breaker has not tripped.
4) Re-initialize the table by pressing and holding the UP s and DOWN t
buttons at the same time until the table moves to its lowest position, then
"bumps up" slightly.
Check that there is adequate space (minimum 1") around all parts of the table,
including moving leg components. Remove any obstacles.
Re-initialize the table by pressing and holding the UP s and DOWN t buttons
at the same time until the control unit beeps and the table moves to its lowest
position, then "bumps up" slightly.
1) Check that the power cord, all motor cables, and control unit cables are fully
plugged in.
2) Check that all cables are undamaged.
3) Check that the circuit breaker has not tripped.
4) Unplug the power cord. Press either button on the handset. Then plug the
power cord back in. Re-initialize the table by pressing and holding the
UP s and DOWN t buttons at the same time until the control unit beeps
and the table moves to its lowest position, then "bumps up" slightly..
1) Check that the fasteners securing the feet to the legs and the legs to the
frame are fully tightened.
2) Check that all fasteners securing the frame to the table are fully tightened.
With a normal load on the table, fully raise and fully lower the table through five
to ten cycles. The vibration or noise should disappear.
Page 10
Troubleshooting
Solution