Alto-Shaam HALO HEAT 300-HST Installazione Funzionamento e manutenzione - Pagina 6

Sfoglia online o scarica il pdf Installazione Funzionamento e manutenzione per Attrezzature per alimenti commerciali Alto-Shaam HALO HEAT 300-HST. Alto-Shaam HALO HEAT 300-HST 18. Hot food shelf electric
Anche per Alto-Shaam HALO HEAT 300-HST: Scheda tecnica (2 pagine)

Alto-Shaam HALO HEAT 300-HST Installazione Funzionamento e manutenzione
E l e c t r i c a l I n s t a l l a t i o n
1.
An identification tag is permanently mounted
on the case.
®
Plug the unit into a properly grounded
2.
receptacle ONLY. Arcing will occur when
connecting or disconnecting the unit unless
all controls are in the "OFF" position.
Position the unit so the cord is easily accessible
3.
in case of any emergencies. If necessary, a
proper receptacle or outlet configuration, as
required for the unit, must be installed by a
licensed electrician in accordance with
applicable, local electrical codes.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
VOLTAGE
120
at 208
at 240
230
I N S TA L L AT I O N
PH
3521030
PATENT NOS.
4595247
ELECTRICAL
/
PHASE
CYCLE
HZ
AMPS
1
60
27.1
1
50/60
12.5
1
50/60
13.4
1
50
14.1
# 8 1 5 O p e r a t i o n a n d C a r e M a n u a l • 5.
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in
close vicinity, an equalization-bonding stud is
provided. An equalization bonding lead must be
connected to this stud and the other appliances /
metal parts to provide sufficient protection against
potential difference. The terminal is marked with
the following symbol.
NOTE:
The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
IMPROPER INSTALLATION, ALTERATION,
ADJUSTMENT, SERVICE OR MAINTENANCE
COULD RESULT IN SEVERE INJURY, DEATH
OR CAUSE PROPERTY DAMAGE.
kW
3.3
NEMA L5-30P
30A-125V PLUG
2.6
NEMA L6-20P
3.2
20A-250V PLUG
3.2
NEMA CEE7/7
16A-250V PLUG
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70.
In Canada, all
electrical connections are to be made
in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.