Indicators
Audible Alarms
Communication
Power Master Software
Environmental
Operating Temperature
Operating Relative Humidity
DEFINITIONS FOR LED & ALARM
UPS Status
UPS is Normal
Battery Mode (No AC)
Low Battery
Overload
UPS is shut down
UPS is malfunction
TROUBLE SHOOTING
Problem
The UPS does not
perform expected
runtime.
The UPS will not
turn on.
Outlets do not
provide power to
equipment
Windows10/ Windows8/ Windows7/ Windows Server2012 R2/ Windows
LED Status
Green LED is always On
Yellow LED is blinking every 30 seconds
Yellow LED is blinking every 2 seconds
Red LED is blinking every 0.5 seconds
All LEDs are Off
Red LED is always On
Possible Cause
Batteries are not fully charged.
Battery is slightly worn out.
The on/off switch is designed to prevent
damage by rapidly turning it off and on.
The unit is not connected to an AC outlet.
The battery is worn out.
Mechanical problem.
Circuit breaker is tripped due to overload
Batteries are discharged
Unit has been damaged by a surge or
spike.
Line Mode, Battery Mode, Fault
On Battery, Low Battery, Overload, Fault
Server2008 R2,
Linux & Mac
0℃ to 40℃
0 to 90%
Recharge the battery by leaving the UPS
plugged in.
Contact Technical Support.
Turn the UPS off. Wait 10 seconds and then
turn the UPS on.
The unit must be connected to a 230Vac
50/60Hz outlet.
Contact Technical Support.
Contact Technical Support.
Turn the UPS off and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then press the circuit
breaker knob.
Allow the unit to recharge for at least 4
hours.
Contact Technical Support.
Page 4 of 5
Alarm
No Beep sound
Beep sound every 30 seconds
Beep sound every 2 seconds
Beep sound every 0.5 seconds
No Beep sound
Constant Long Beep Sound
Solution
Version: 2020/07