Preventative Maintenance and Servicing
Operation
Drain Air Receiver
Replace Air Intake Filter
Check Pressure Relief Activation
Clean Ventilation Grilles
Check Piston Ring
Above are to be considered minimum frequency
Part number BPPT1 (service kit for PT pump) covers all models
The PT90 requires three service kits while the PTS20 requires one kit
Technical
PT Pump Specification
Motor - kW / Hp
Voltage
Frequency - Hz
RPM
Displacement – L/Min
We recommend the compressor has a maximum 65% duty cycle to prolong pump life
Note !
The motor must never be allowed to run continuously, otherwise it will overheat and
may become damaged. The duty cycle is calculated over 10 minutes, meaning that if
the motor runs for 6.5 minutes it must rest for 3.5 minutes before its next use.
Do not ignore air leaks. All air connections must be leak free to prevent the
compressor from overheating.
The compressor is fitted with a thermal overload. In the event of excessive
temperature, the motor will switch off. After about 50 minutes when the motor has
cooled it will automatically reset.
You must find the cause of the overload and rectify it before continuing to use the
compressor. Damage by continuing to use the unit is not covered under warranty.
Daily
•
0.75 / 1.0
220/240
50
1450
128
5
Annually
2 Years
•
•
•
•