PB-170 Brake
For Bore sizes
see chart below .
Std . Armature
Antibacklash
Armature
Armature View
1 .812 Max . Sq .
Magnet View
*Mount ing holes are within .010 of true position relative to pilot
diameter .
Customer Shall Maintain:
1 . Squareness of brake mounting face with armature
shaft within .006 T .I .R .
2 . Concentricity of brake mounting pilot diameter with
armature shaft within .010 T .I .R .
12 Warner Electric • 800-825-9050
2 .437/2 .435 Pilot Diameter
45°
.204/ .187 dia . (4)
holes equally spaced
on 2 .125 diameter*
Send Quote Requests to [email protected]
Call +1(800)985-6929 To Order or Order Online At Warnerelectricparts.com
Call +1(800)985-6929 To Order or Order Online At Warnerelectricparts.com
.015 When New
.086 (Std .)
.094 (Anti .)
.125 (Std .)
.109 (Anti .)
.625
Std .
Arm .
1 .718
Max .
.843
Dia .
Anti .
Arm .
.515
1 .375 Max .
Bore Di men sions
Armature Bore Dia.
.251/ .250
.313/ .312
.376/ .375
Shaft Sizes
Static Torque
Maximum Speed
Standard Voltage
.390
12
Min .
.062
.752/ .750
Pilot Dia .
#8-32
UNC-3A
.015
.086 (Std .)
.094 (Anti .)
.437
Max .
.812
.250 – .375
15 lb . in .
10,000 rpm
D .C . 6, 24, 90
P-201-WE • 819-0480