Dixon Bayco FT590 Series Istruzioni per la manutenzione e il funzionamento - Pagina 5

Sfoglia online o scarica il pdf Istruzioni per la manutenzione e il funzionamento per Apparecchiature di prova Dixon Bayco FT590 Series. Dixon Bayco FT590 Series 6.

Troubleshooting

• The FT590 Rack tester is working intermittently or has stopped working completely.
Clean the socket connection on the FT590 using an abrasive pad.
• The FT590 tester is sending intermittent signals depending on how I hold it.
The optic probes are sensitive to sun light and incandescent lights. Shielding the probe
tip from these light sources will eliminate the issue.
• The trailer's On-Board-Monitor (OBM) shows permissive, and the FT590 rack tester
has verified the rack monitor operation, but the trailer cannot load.
The issue is likely in the wiring from the OBM to the trailer socket, or the socket itself.
• The rack uses Trailer Identification Modules (TIM). How can the FT590 rack tester be
used to verify TIM reading is working?
An FT590 model including a TIM will be required. FT590OGT and FT590TGT both include
a TIM module. When the rack tester is initially connected, it will be recognized as an un-
registered trailer. A rack operator will need to enter the serial number from the FT590's
internal TIM into the terminal automation system. Once the FT590's TIM serial number
is registered, it can be used as outlined in the operation section above.

Warranty

For warranty claims and information regarding coverage, service, repairs, or troubleshooting,
please contact the 24 hour Dixon Tech-Support line at: +1 (877) 582-3569.
REV A 2020/10/15
FT590 SERIES RACK TESTER MANUAL; 11266PA
877.582.3569
5