Dixon Bayco FloTech FT208 Manuale - Pagina 13

Sfoglia online o scarica il pdf Manuale per Monitor Dixon Bayco FloTech FT208. Dixon Bayco FloTech FT208 20. Checkmate programmable retain / overfill onboard monitor

5. Turn on the power. The sensor LEDs will sequentially flash through the power up test pattern. This
lights the sensor LEDs individually from TOP #1 through TOP #8 and then through BOTT #1 through
BOTT #8.
6. The sensor LEDs will light up the last valid configuration. If the memory does not contain a valid
configuration, the sensor LEDs will default to lighting the top 1 sensor.
7. Press SW2 pushbutton to light the RED Top and Bottom Sensors light to match the total number of top
and bottom sensors. Each time SW2 is pressed, the sensor LEDs will shift to the next valid
configuration. This sequence is Top #1 to Top #8 and then Top and Bottom #1 to Top and Bottom #8.
This sequence will repeat every time the pushbutton is pressed.
8. Once the LED pattern representing the number of connected sensors is correct, move SW1 to "RUN"
position. The monitor will flash the sensor LEDs sequentially through the test pattern. At this point, if
all connected sensors are dry and the AUX LED is on, the PERMIT LED should light and no RED
LEDs are lit.
9. Remove power from the trailer or turn power off to the monitor. Remove the programming module,
reconnect the retain reset switch, and turn power back on to the monitor.
10.

Operation

Normal Operation

When power is applied to the FT208 monitor, the unit will sequentially flash the sensor LEDs through the
power up test pattern. This sequence is from the TOP #1 LED to the TOP #8 LED then from the BOTT #1
LED to the BOTT #8 LED.
Once this sequence is completed, the unit tests all the sensor inputs.
FloTech Programmable CheckMate Retain / Overfill Monitor
PROGRAM MODULE POSITION
FT208 CheckMate
FIG. 11
10466 REV N
13