After the animation finished, the menu item of the gauge is displayed. The EDMS
mode will be where the user left it during its last use. This feature designed in the
system so the user can choose their favorite setting and return to it without needing
to scroll through the menu.
The operating cycle of the manometer consists of three stages-modes:
1. Operating mode, the screen is on
The pressure gauge displays the current data, and after 5-7 seconds it
turns off the screen and goes to the second stage "Operating mode, the
screen is off."
Each press of the button prolongs the time of the manometer in the first
stage.
2. Operating mode, the screen is off
a.
The pressure gauge continues to function for another 40 seconds with
the screen off (that is, it records the pressure change and, if any, turns on the
screen).
b.
Pressing the button brings you to the first stage and activates the screen.
c.
If the stage time has expired, then the stage 3 - the "sleep" mode is
engaged.
3. Sleep mode stage
d.
The pressure gauge goes into reduced consumption mode. The
pressure sensor is not interrogated, the screen is off. That is, if the
pressure changes (shot or pumping), the pressure gauge will not show
a display.
e.
Exit the sleep mode by pressing the button.
2. Menu of the gauge
The layout of the title menu is shown in the picture:
1
2
3
4
5