Sfoglia online o scarica il pdf Procedura di manutenzione per Generatore portatile ClearWater CD-2000. ClearWater CD-2000 2. Annual maintenance procedure ozone generator
Maintenance of the ozone system is critical to its longevity and operating efficiency. Follow the steps below to perform the
preventative annual maintenance. If you have additional questions regarding the maintenance of your ozone installation, please consult
the operation manual or contact your dealer.
Before you start:
System Shutdown Procedures
Step 1: Turn off power to any peripheral
system hydraulic components and
air prep system.
Step 2: Turn the Main Power switch on
the ozone generator to the "OFF"
position.
Step 3: Disconnect the power to the ozone
system at the service disconnect
box (if so equipped), main circuit
breaker or by disconnecting the
power cord.
Included in this maintenance kit:
Pictured are overview images of the CD2000 and the contents of a CD2000
maintenance kit.
Numbered items correspond to descriptions below and their installed locations within
the ozone generator.
M1500, CD1500 & P2000 systems will have similar maintenance kits and generator
layouts. They will have differences in quantity of parts and type of circuit boards
however the steps will be the same.
The M1500 & CD1500 models will have a single set of o-rings (#5), as the units have
one reaction chamber.
Maintenance Will Involve the Following:
1. Cooling Filter: Clean or replace the cooling fan filter elements as required.
2. Inline Particulate Filter: Remove colored protective caps before installing the
new filter. Re-tape threads with Teflon tape. Orientation is universal.
3. Check Valves: Replace both check valves (one at the ozone generator and one at
the injector). Make note of check valve direction before removing old check valve
and reinstall new valve in same direction. Re-tape threads with Teflon tape.
4. Fuses: Save the replacement fuses for use as needed.
5. Reaction Chamber O-Ring Replacement: See page 2 for reaction chamber
maintenance instructions.
ClearWater Tech, LLC.
1.800.262.0203 • 805.549-9724
850-E Capitolio Way, San Luis Obispo, CA 93401 • email: [email protected] • www.cwtozone.com
Annual Maintenance Procedure
FOR USE WITH M1500, CD1500, P2000 & CD2000
Recommended Tools
Nut Driver: 11/32", 3/8"
Screwdrivers: Phillips and flat-
head
O-Ring Removal Pick
Hex Key: 7/64", 9/64" (for
CD1500)
Wrench: 5/8" or adjustable
2" Ball hone (optional)
Cloth Shop Towel
Denatured Alcohol
Scissors
Teflon Sealing Tape
Video Walkthroughs
Visit our video channel at:
http://www.youtube.com/ClearWaterTech
These, and other procedures are shown.