8. Fault Finding
If a fault should occur during start-up self-test or subsequent operation, then all four
green status LEDs will flash in unison for 30 seconds, while the distance display will give
an indication of the most serious fault. The fault display can be stopped before 30 sec-
onds has elapsed by pushing the button "Mode". For safety reasons ECW100 will not start
up if there is a fault. ECW100 may not be used if a fault has been reported or indicated.
Limited operation is possible if there is an indication of a problem with the obstacle data
bank or data recorder.
11 Fault:
12 Fault:
21 Fault:
31 Fault:
32 Fault:
41 Fault:
42 Indication:
51 Fault:
61 Fault:
71 Fault:
81 Indication:
82 Indication:
91 Indication:
93 Indication:
a1 Indication:
b1 Indication:
f1
Fault:
1 Indication:
The communications faults itemized above indicate if internal modules within ECW100
are not communicating correctly with each other. For reasons associated with the sys-
tem, reduced radio range cannot be detected by a single unit alone.
Software-Versions 7.xx will only operate until October 31, 2021. After this date, you
must update the device in order to use it in the air. On publication the update will have
no functional changes and can be downloaded free of charge. Users will be able to load
the software with the SD card. Software validity has to be time-limited to ensure that all
ECW100 units are mutually compatible and that updates include the latest obstacle data.
Software out of date (needs GPS reception)
Software integrity violation
(only on IGC-units)
Low Voltage
Internal GPS communication
Faulty GPS configuration
Internal radio communication
other FLARM-Unit with the same RF ID
General internal communication
Flash memory
Pressure sensor
No obstacle data base
Old obstacle data base
Flight recording not possible
Engine-noise recording not possible
(only on IGC-units)
Configuration file on SD card faulty
Obstacle data base license invalid
Other fault
Configuration file on SD card faulty
No operation
No operation
No operation
No operation
No operation
No operation
Operation possible
No operation
No operation
No operation
Operation possible
Operation possible
Operation possible
Operation possible
Operation possible
Operation possible
No operation
Operation possible
Page 8