AIMS Power PV6X120RACK Manuale di installazione - Pagina 6
Sfoglia online o scarica il pdf Manuale di installazione per Inverter AIMS Power PV6X120RACK. AIMS Power PV6X120RACK 16. Ground mounting system
![AIMS Power PV6X120RACK Manuale di installazione](/uploads/products/server2/84509/84509.jpg)
Base Foot Dimension:
Using M10 Grade 5.8 Carbon Steel anchor studs with Ramset Chemset REO502 chemical
injection anchoring system. Minimum anchor embedment depth of 90mm with concrete
strength of 32MPa. There are several ways to mount the racks depending on application
6
and structural guidelines. Check with local area.