INTENDED USE:

The Aviator is designed to blow air across wet surfaces for speed drying. The high-volume airflow
from the Aviator increases the rate of evaporation, helps prevent mold growth, and reduces the risk of
additional moisture damage.

POSITION SWITCH:

The 3-position drying mode selector switch is used to select the Aviator's mode of operation. The 3
modes of operation are OFF, LOW or HIGH.
GFCI Protection and the OnBoard Duplex Vac Outlet:
The standard AC voltage outlet GFCI (Ground Fault Circuit Interrupter) protection promotes operator
safety in wet applications. GFCI devices trip when a fault to electrical "ground" is sensed.
It is recommended to check the GFCI protection prior to operation. To check, push the "TEST" button
located of the GFCI duplex outlet. If operating properly, the "RESET" button on the GFCI will pop out.
This duplex AC outlet allows the Interconnection of the other AC powered devices. The sum total
amperage of all devices plugged into the receptacle must not exceed 9 amps.

DAISY CHAINING:

The Aviator draws 2.3 amps. The 12 amp onboard circuit breaker will allow four (4) Aviators on one
circuit. Five (5) is too many for one circuit. When daisy chaining the Aviator, turn on one Aviator at a
time to prevent excessive current inrush caused by four units starting at once.
A ground fault in the Aviator or anywhere on the circuit will cause the Aviator's GFCI to trip. After
rectifying the ground fault, reset the GFCI by pressing the reset button.

OPERATING PROCEDURES:

Plug the Aviator into a standard grounded outlet with correct voltage and amperage. Turn on the
switch and check that the unit operates properly before leaving it unattended. Do not carry or move
the Aviator when it is running.

MAINTENANCE:

1. Disconnect the power cord from the outlet before performing this maintenance procedure.
2. Inspect the electrical cord and wiring for damage or discoloration.
3. Inspect for loose fasteners.
4. Clean screens on the side and front of the unit.
5. Listen for abnormal sounds.
6. Keep unit clean.
7. Motor does not require lubrication.