Altronic CDM-2100 Manuale operativo - Pagina 13

Sfoglia online o scarica il pdf Manuale operativo per Strumenti di misura Altronic CDM-2100. Altronic CDM-2100 20. Differential pressure monitor

Altronic CDM-2100 Manuale operativo
10.4 40000 SERIES REGISTERS
ADDRESS
DESCRIPTION OF FUNCTION
40001
Coils 001-016
40002
Coils 017-032
40003
Coils 033-048
40005
Node Number 1-99
40006
Baud rate Index
0=9.6k 1=19.2k 2=38.4k 3=57.6k 4=115.2k
40007
Security Password 000-999
40009
RESERVED
40010
RESERVED
40011
Lag Filter Gain (1-255)
40012
SENSOR TYPE
CUSTOM
0=Custom
PRESSURE SENSORS
256=15psi
260=300psi
264=5000psI
TEMPERATURE SENSORS
512=JTC
516=Custom Temperature
VIBRATION SENSORS
Velocity
Acceleration
PERCENT
1280=0–100% (0-55Vdc) 1281=Custom Percent
VOLTAGE
1536=0-5Vdc 1537=±160mVdc 1538=±80mVdc
1539=Custom Voltage
40013
Units Index (class specific)
PRESSURE SENSORS
0=psi
6=inH2O@20C
10=kg/cm2
TEMPERATURE SENSORS
0=Kelvin
VIBRATION SENSORS
Velocity
Acceleration
40014
A/D Voltage Range
0=5V
40015
SENSOR MAX (float) (msw)
40016
SENSOR MAX (float) (lsw)
40017
SENSOR MIN (float) (msw)
40018
SENSOR MIN (float) (lsw)
40019
Range HI (float) (msw)
40020
Range HI (float) (lsw)
40021
Volt HI (float) (msw)
40022
Volt HI (float) (lsw)
40023
Range LO (float) (msw)
40024
Range LO (float) (lsw)
CDM-2100 OM 3-21
All rights reserved © ALTRONIC, LLC 2021
257=25psi
258=50psi
261=500psi
262=1000psi
265=10000psi 266=Custom Pressure
513=KTC
514=DEG1
515=DEG2
768=1ips
769=2ips
770=Custom Velocity
1024=10g 1025=20g 1026=50g
1027=Custom Acceleration
1=psig
2=psia
3=Kpa
4=bar
7=inHg
8=mmH2O
11=torr
1=Celsius
2=Fahrenheit
0=in/s
1=mm/s
2=cm/s
0=G
1=ft/s/s
2=m/s/s
1=±160mV
2=±80mV
259=100psi
263=2000psi
5=mbar
9=mmHg
13