Altronics Q0965 Manuale di avvio rapido
Sfoglia online o scarica il pdf Manuale di avvio rapido per Strumenti di misura Altronics Q0965. Altronics Q0965 2. High current ac/dc clamp meter 600a
Q0965 • High Current AC/DC Clamp Meter 600A
1. SUMMARY
This 3 5/6 Digit Highly Stable clamp meter uses two AAA (1.5V) batteries. It has a LCD with 18mm
digit display, which makes the reading clearer and the operation more convenient. It can test DCV, ACV,
DCA, ACA, resistance, capacitance, frequency, temperature, diode, continuity, as well as non-contact
AC voltage test. It is equipped with clamp jaw lighting, Backlight, unit symbol display, True RMS, data
hold function, Relative measurement, auto power off and warning functions. It works in both auto range
and manual range. To assure high accuracy and resolution, it adopts a micro-processor which drives the
LCD directly and a dual integral A/D converter IC. It is an ideal tool for labs, factories radio-technology
and household.
2. SAFETY NOTICE
The instrument is designed according to IEC1010-1 standard (safety standard issued by International
Electro technical Committee), CAT III 600V and UL3111-1. Please read the followings carefully before
any operation.
1. Introduction for safety symbols:
: Existing High Voltage.
: Dual Insulation.
: Operator must refer to manual.
battery indication.
2. Notice:
(1) Please disconnect any signal and pluck out the test leads before opening the outside cover.
(2) To avoid electric shock and damage to the meter, water should not be leaked inside.
(3) DO NOT use this meter to do any test if the case hasn't finished installation and its screws haven't
been tightened.
(4) DO NOT input the value higher than the limit at every range.
(5) Please don't input voltage in resistance terminal.
(6) Please turn the power switch to OFF after the test.
(7) To avoid the damage of battery leakage to the meter, please remove the battery for long-term storage.
(8) To avoid electric shock and damage to the meter, do not input voltage higher than DC 60V or AC
36V during the measurement.
(9) To avoid electric shock, please be seriously careful when nipping the bus bar or something insulated.
3. FEATURES
1. GENERAL FEATURES
(1) Display: LCD.
(2) Max. display: 6000 digits (3 5/6) , and auto polarity display .
(3) Clamp open: Max. Open: 28mm.
(4) Over-range display: "OL" displayed.
(5) Data hold.
(6) Relative Value measurement.
(7) Sampling rate: approx.3 times/sec.
(8) Low battery indicator: "
"displayed.
(9) Continuity test: buzzer sounds when<50Ω.
(10) Range: Auto range or Manual range.
(11) Auto power off.
(12) Power consumption: about 3mA.
(13) Power: 2 × 1.5V batteries (AAA 7#battery).
(14) Working environment: (0~40)℃, relative humidity: <70%.
(15) Dimension: 185mm× 65mm× 32mm (length × width × height).
(16) Weight: approx. 200g (including battery).
(17) Accessories: user manual, test leads, temperature sensor TP01 banana probe, two AAA batteries.
2. TECHNICAL FEATURES
(1) Accuracy: ± (a% × reading data + digits). To assure accuracy, the environment temperature should
be (23± 5) ℃, relative humidity be <70%. One year accuracy guarantee since production date.
(2) Temperature coefficient: 0.1× specified accuracy/1℃(<18℃ or>28℃).
(3) DC voltage (DCV)
Range
Accuracy
Resolution
600mV
± (1.0% reading+5)
6V
60V
± (0.5% reading+5)
600V
100mV
Input impedance: at 600mV range >40MΩ, at other ranges is 10MΩ.
Overload protection: 1000Vrms.
(4) AC voltage (ACV)
Range
Accuracy
Resolution
6V
60V
± (0.8% reading+5)
600V
100mV
Input impedance: 10MΩ.
Overload protection: 1000Vrms.
Frequency response: 600V at 40Hz~1kHz, other ranges 40Hz~2kHz.
Display: True Rms Response (calibration base on Sine Wave RMS).
(5) DV Current (DCA)
Range
60A
600A
800A
Overload protection: 1000A (input time <60 seconds).
NOTE: Clear to zero before measurement,The testing object shall be placed in the middle of the clamp
jaw.
(6) AC current (ACA)
Range
60A
600A
800A
Frequency response: Sine wave and triangle wave 40Hz- 1kHz; other waveforms 40Hz-200Hz.
: Low
Overload protection: 1000A (input time <60 seconds)
NOTE: The testing object shall be placed in the middle of the clamp jaw.
(7) Resistance
Range
600Ω
6kΩ
60kΩ
600kΩ
6MΩ
60MΩ
Open circuit voltage: 500mV, Overload protection: 250Vrms.
NOTE: DO NOT input any voltage value at this range!
(8) Capacitance
Range
6nF
60nF
600nF
6uF
60uF
600uF
6mF
60mF
Overload protection: 250Vrms. Warning: DO NOT input voltage value at this range!
(9) Frequency
Range
10Hz
100Hz
1kHz
10kHz
100kHz
1MHz
10MHz
Input sensitivity: >0.7V. Overload protection: 250Vrms.
(10) Temperature
Range
(-40~1000 )℃
0.1mV
1mV
(0~1832 )℉
10mV
Sensor: K type banana plug (Nickel-chromium-Nickel silicon).
Warning: DO NOT input voltage value at this range!
(11) Continuity Test
Range
1mV
10mV
Overload protection: 250V TRMS.
Warning: DO NOT input voltage value at this range!
4. OPERATION
Accuracy
Resolution
0.01A
± (1.5% reading+5)
0.1A
1A
Accuracy
Resolution
0.01A
± (1.5% reading+5)
0.1A
1A
Accuracy
Resolution
0.1Ω
± (0.8% +5)
1Ω
10Ω
± (0.8% +1)
100Ω
1kΩ
10kΩ
± (1.0% +5)
Accuracy
Resolution
± (5.0% +10)
1pF
10pF
100pF
± (2.5% +5)
1nF
10nF
100nF
± (5.0% +10)
1uF
10uF
Accuracy
Resolution
0.01Hz
0.1Hz
1Hz
± (0.5% reading+4)
10Hz
100Hz
1kHz
10kHz
Accuracy
Resolution
<400℃:
± (1.0%+5)
1℃
≥400℃: ± (1.5%+15)
<750℉: ± (1.0% + 5)
1℉
≥750℉: ± (1. 5% + 15)
Description
Test Conditions
Forward DC current is approx0.8mA,
Diode forward voltage drop
reverse voltage is approx2.2V.
When the resistance under test is less
Open circuit voltage: 2V
than 50Ω, buzzer sounds continuously.
4.1 PANEL DESCRIPTION
(1)
: 0 to 800 AC current and NCV detecting device.
Jaw
(2) Clamp gunlock: Pressing the gunlock can turn on or off
the clamp.
(3) Hand protection: A safe design to protect users from
touching the dangerous area.
(4) Clamp light: Opening the clamp light can light up the
tested area in the dark to prevent the danger.
(5) NCV indicator: Detect the existence of the high voltage
around to prevent the electric shock.
(6) Function choosing switch: Used to select the function, range or turn on or turn off
the clamp meter.
Function
Description
NCV
Non-contact voltage test.
DCA, ACA measurement.
ACV measurement. Press "Hz/DUTY" to switch to Frequency/Duty cycle
measurement mode.
DCV measurement.
Press "SELECT" to switch to Diode, Continuity, Capacitance and Resistance
measurement mode.
Hz
Frequency measurement.
℃/℉
Temperature measurement. Press "SELECT" button to switch to ℃ or ℉.
(7) Function
key.
SELECT /
KEY:
1) This is a key for Selecting function, Base on a working principle of Trigger action. Short press this
key to choose measurement modes: Choose DC or AC at "
", choose"Ω →
choose "℃" or "℉" when at Temperature range.
2) The Meter will be Auto-power off when it is not being using within 15 minutes, then it will be
entering into sleeping mode, the Buzzer will makes 5 times of alarm reminder within 1 minute before
Auto-power off; Please press this "SELECT" function or Power on/off button to turn on the Power if you
want to restart it.
3) Press this key and put it on Hold and then turn on the Power to awake it from sleeping mode, and then
Auto-power off function will be canceled.
4) Illuminating lamp control key, press it for more than 2 seconds to turn on Illuminating lamp, and then
press it for more than 2 seconds again to make it off.
5) Backlight control key, press it for more than 2 seconds to turn on Backlight (it will be shown on LCD)
then press it for more than 2 minutes again to make it off. Backlight function will be off automatically
when you release backlight control key after 30 minutes.
△/ RANGE key:
measurements, it is REL function. Press this key to clear "of readying" and enter
1.In
and
relative value measurement. REL symbol will appear on the LCD. Press this key again to exit REL
measurement. In
and
measurements, if the display dose not return to zero before measurement,
press this key to return to zero before measurement.
2.In voltage and resistance measurements, it is RANGE function, to choose from auto range or manual
range. The meter is default in auto range. The symbol "AUTO" appears on LCD. Press this key for one
time to switch to manual range. Press it again for one time to increase on step from low to high. Press it
for more than two seconds to return to AUTO range.
Hz/DUTY KEY: In ACA/ACV measurements, press this key to switch measurement between frequency,
duty ratio, voltage and current. In frequency measurement, press this
key to switch between measurement of frequency and duty ratio
(1-99%).
HOLD/
KEY:
1) It is a key for Data Hold, Base on a working principle of Trigger
action, short press this key to keep the current Data of measurement
on LCD, LCD will show symbol "
", press this key again to exit
Data Hold.
(8)
LCD:
Displaying
measurement value and unit.
Sequence
Functions
Auto power off function has been activated,
1
APO
MAX-MIN
MAX/MIN Null.
2
△
Relative measurement.
3
HOLD
Data hold
4
-
Indicates negative readings.
5
DC
DC measurement.
6
AC
AC measurement.
7
AUTO
Auto range.
" at "
" ,
→
→
Description
High pressure warning.