EDILGRAPPA MU 22N Istruzioni per l'uso e la manutenzione - Pagina 12

Sfoglia online o scarica il pdf Istruzioni per l'uso e la manutenzione per Utensile elettrico EDILGRAPPA MU 22N. EDILGRAPPA MU 22N 20. Machine body with interchangeable heads

MU 22N

3 ROUTINE MAINTENANCE

1. All maintenance, inspection and cleaning operations must be performed
with the power supply disconnected and the machine cool (see the person
responsible in the maintenance schedule);
2. Maintenance operations must be performed in a suitable place according to
3. Before any maintenance intervention, thoroughly clean the machine (see
4. Wear suitable personal protective equipment while performing maintenance
AFTER MAINTENANCE WORK, MAKE SURE THE GUARDS ARE PUT BACK INTO
THEIR CORRECT PLACE.
Frequency
EVERY 8 HOURS
/
EVERY 1600
HOURS
EVERY 8 HOURS
If you have any doubts about ordering spare parts or performing complex
maintenance work, contact your authorised dealer.

3.01 CHANGING AND TOPPING UP THE OIL

When changing or topping up the oil, make sure no impurities contaminate the oil or enter
the tank. Impurities in the oil can irreparably damage the hydraulic components.
ALWAYS MAKE SURE THE OIL CONTAINS NO IMPURITIES
DO NOT USE DIRTY TOOLS
DO NOT WORK IN DUSTY AREAS
CHANGING THE OIL:
USING A SUITABLE DISPENSER, PREPARE THE CORRECT QUANTITY OF OIL (0.6
l) TO POUR INTO THE TANK.
LEAKING OIL CAN CAUSE SHORT CIRCUITS, FIRE AND EXPLOSIONS.
1. Place the machine horizontally in a stable position on a work surface with the magnetic
cap (fig. 3) facing upwards. Place a basin under the machine to catch any oil leaks;
2. Unscrew the magnetic cap (fig. 4) and remove any residues with the piston in its
retracted position;
12
current safety regulations;
Paragraph 5.01);
work.
Periodic maintenance schedule
· CHECK
THE
MACHINE
· CLEAN THE PISTON
· CHANGE THE OIL
· CHECK THE TIGHTNESS OF NUTS AND
BOLTS
Operation
INTEGRITY
OF
Method
THE
Visual
Para 3.04.01
Para 3.01
Para 3.02
Person
Operator
Operator
Maintenance
man
Operator