EdilKamin LOGO Manuale di installazione, uso e manutenzione - Pagina 17
Sfoglia online o scarica il pdf Manuale di installazione, uso e manutenzione per Stufa a legna EdilKamin LOGO. EdilKamin LOGO 20.
POSSIBLE TROUBLESHOOTING
,Q WKH HYHQW RI SUREOHPV WKH VWRYH VWRSV DXWRPDWLFDOO\ DQG UXQV WKH VKXWGRZQ SURFHVV DQG WKH GLVSOD\ VKRZV WH[W
UHJDUGLQJ WKH PRWLYDWLRQ RI WKH VKXWGRZQ VHH WKH YDULRXV DODUPV EHORZ
1HYHU SXOO WKH SOXJ GXULQJ VKXWGRZQ RQ DFFRXQW RI PDOIXQFWLRQ
6KRXOG LW EORFN WR UHVWDUW WKH VWRYH \RX ZLOO QHHG WR DOORZ WKH WXUQRII SURFHGXUH WR WDNH SODFH VHFRQGV ZLWK
DXGLEOH VLJQDO DQG WKHQ SUHVV WKH EXWWRQ
'R QRW WXUQ WKH VWRYH RQ DJDLQ EHIRUH FKHFNLQJ WKH FDXVH RI WKH PDOIXQFWLRQ DQG &/($1,1* (037<,1* WKH FUXFLEOH
,1',&$7,21 2) 3266,%/( &$86(6 2) 0$/)81&7,21 $1' ,1',&$7,216 $1' 5(0(',(6
1) 6LJQDOOLQJ 9HUL FDLU RZ (intervenes if the ow sensor detects insuf cient combustion ).
3UREOHP
7XUQV RII IRU ODFN RI GHSUHVVLRQ
$ir ow ma\ be insuf cient because the door is open, the door does not close properl\ (e.g. bad seal), there is an
air intake or smoke e[traction problem, or the combustion chamber is clogged.
&heck
$FWLRQV
door closure;
combustion air intake duct (clean, pa\ing attention to the ow sensor components);
clean the ow sensor with dr\ air (like that used for 3& ke\boards);
stove location it must not be installed against a wall;
combustion chamber position and cleanliness (clean regularl\ according to the t\pe of pellet);
smoke duct (clean);
installation (if it does not compl\ with regulations or the smoke outlet has more than - bends);
,f \ou suspect the sensor is malfunctioning, carr\ out cold tests. ,f the conditions are changed (for e[ample b\
opening the door) and the value does not change, there is a sensor problem.
7he no depression alarm ma\ also occur during ignition, since the ow sensor starts monitoring 9 seconds after
1%
the ignition c\cle begins.
6LJQDOOLQJ
9HUL FH[WUDFW (this trips if the smoke e[traction speed sensor detects a fault)
3UREOHP
6KXWGRZQ IRU VPRNH H[WUDFWLRQ VSHHG IDXOW GHWHFWLRQ
$FWLRQV
&heck smoke e[tractor function (devolution sensor connection) and board ('E$LER).
&heck smoke channel for dirt
9erif\ the electrical s\stem and earthing s\stem.
&heck eletronic circuit board ('E$LER).
6LJQDOOLQJ
6WRS)ODPH (this trips if the thermocouple detects a smoke temperature lower than the value set, which it
interprets as the absence of ames)
3UREOHP
7urns off due to drop in smoke temperature
$FWLRQV
lack of pellets
too man\ pellets have suffocated the ame, check pellet qualit\ ('E$LER)
the ma[imum thermostat has intervened (rare, this onl\ intervenes in the event of e[cessive smoke
temperature) ('E$LER)
%ORFNB),12 6WDUW (intervenes if a ame fails to appear within a ma[imum of minutes, or if ignition
6LJQDOOLQJ
temperature is not reached).
3UREOHP
7XUQV RII GXH WR LQFRUUHFW VPRNH WHPSHUDWXUH GXULQJ LJQLWLRQ
'istinguish either of the following cases
)ODPH GRHV 127 DSSHDU
&heck - combustion chamber position and cleanliness;
$FWLRQV
arrival of combustion air in the combustion chamber;
if the heating element is working ('E$LER);
room temperature (if lower than q& use a relighter) and damp.
7r\ to light with a relighter (see page 9).
)ODPHV DSSHDU EXW $) DSSHDUV RQ WKH GLVSOD\ DIWHU $U
&heck (onl\ b\ the 'ealer)
$FWLRQV
if the thermocouple is working ('E$LER);
start-up temperature setting in the parameters ('E$LER).
Repeat start up after having empt\ing the bra]ier.
6LJQDOOLQJ
%ODFN 2XW (not a defect of the stove).
3UREOHP
7XUQV RII GXH WR ODFN RI HOHFWULFLW\
&heck electricit\ connection and drops in voltage.
$FWLRQV
6LJQDOOLQJ
)DXOW5& (intervenes if the thermo coupling has failed or is disconnected).
3UREOHP
7XUQV RII GXH WR WKHUPR FRXSOLQJ IDLOHG RU GLVFRQQHFWHG
&heck connection of thermo coupling to board check function in cold test ('E$LER).
$FWLRQV
- 35
-