Sfoglia online o scarica il pdf Manuale per Attrezzature per il fitness Fitness Technoligies Force Plate 400 Series. Fitness Technoligies Force Plate 400 Series 18. Replacing a load cell
Once all the cable ties are cut you can pull the cable from the end that was connected to the Molex connector to
remove the cable from the force plate.
Once the cable is free you will be able to remove the load cell.
It is important here to pay attention to the
orientation of the load cell.
As we must insure that the load cell is replaced in the same orientation. Gently remove
the load cell until the load cell spacer plate is visible. Remove this and put it to the side.
You can then remove the load cell completely.