Isotherm
Enabling Isotherm allows designated temperature ranges to be represented with different color
schemes, so that objects measured in a single color scheme impart higher contrast and better
visibility.
Individual isotherms (or color schemes) are separated by upper, middle and lower thresholds, which
have a value in percentage or temperature.
Take the White Hot Isotherm as an example. Below the lower threshold, 128-Grayscale is used to
represent temperature differences.
Between the lower and middle thresholds, Color Scheme 1 (48-Isotherm) is used.
Between the middle and upper thresholds, Color Scheme 2 (48-Isotherm) is used.
Above the upper threshold, Color Scheme 3 (32-Isotherm) is used.
Color Scheme 1 (48-Isotherm)
Color Scheme 2 (48-Isotherm)
Color Scheme 3 (32-Isotherm)