5. Cable Testing, place appropriate adapter onto
OPM receiver, select and plug in cable (Single
Mode or Multimode according to cable the cable
being tested), between OLS and OPM.
*Aqua = Multimode. Yellow= Single Mode*
theFOA.org
8A. Single-ended Testing:
Unplug Reference Cable connector from OPM
power meter side ONLY. Place appropriate
type feed through (LC or SC) adapter onto
connector on end of cable.
Plug installed cable to be tested into adapter
at end of cable from OLS and other end into
top of OPM. OPM will now display loss of the
installed cable
Refer to the included FOA instructions "Guide to Fiber Optics & Premises Cabling" to perform A>B and B<A testing to
properly diagnose high loss connector terminations.
For accurate testing, frequent cleaning of all connector faces being placed under test, maintaining minimal bends and
movement of reference cables, and resetting of power meter reference throughout the course of testing are recommended.
CLEERLINE™
TEchnology group
theFOA.org
6. Cable Testing, place appropriate adapter onto
OPM receiver, select and plug in two cables,
one into OLS and other into OPM (Single Mode
or Multimode according to the cable being
tested). Link cables together with appropriate
type adapter.
*Additional cables are required for double
ended testing of SC, ST, and FC types.
theFOA.org
Meter
8B. Double-ended Testing:
Unplug one Reference Cable from the
feed thru adapter and install additional
adapter on that open connector.
Plug installed cable to be tested into adapters,
one at OLS side and other at OPM side. OPM
will now display loss of the installed cable.
Test Kit Quick Start Guide
7.Reference OPM.
Once Reference cable/s only are connected
between OLS and OPM units, Quick Press the
"REF" button on the OPM unit. OPM should
then read 0.00 dB on its display"
*Do not press REF again unless ONLY
Reference cables are installed between
OLS & OPM as show in Box 5 or 6
*Performing Step 7 removes the
power loss of the "reference" cables
so that the dB loss reading of the
installed cables will not include the
loss of the reference cable(s) utilized.